FireCADCalc

Pipe Support Span from Stress and Sag

Largest span between supports of a horizontal pipe full of liquid, from its weight, an allowed bending stress and an allowed sag, treated as a beam.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserPump

Inputs

Examples: DN150 (168.3 x 7.11) water-filled, 100 N/m insulation, simply supportedSame pipe treated as fixed at both endsDN50 (60.3 x 3.91) gas line, 50 N/m

Results

Straight run with uniform weight only; valves, flanges, bends and vertical runs need shorter spans. Code span tables, where your code has them, govern.

Total weight per length560.02N/m
Second moment of area of the pipe1,171.6cm⁴
Section modulus of the pipe139.23cm³
Span limited by stress10.924m
Span limited by sag7.9611m
Largest span (the smaller of the two)7.9611m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: DN150 (168.3 x 7.11) water-filled, 100 N/m insulation, simply supported. The inputs, in the units selected above:

InputValue
Pipe outside diameter168.30 mm
Wall thickness (less corrosion allowance if you wish)7.1100 mm
Pipe material density7,850.0 kg/m³
Contents density (0 for gas)1,000.0 kg/m³
Insulation, cladding and other weight per length100.00 N/m
Modulus of elasticity200.00 GPa
Allowed bending stress from weight (your design value)40.000 MPa
Allowed sag at mid-span2.5000 mm
Treat the span asSimply supported (wL²/8, 5wL⁴/384EI)

Applying the formula below gives:

ResultValue
Total weight per length560.02 N/m
Second moment of area of the pipe1,171.6 cm⁴
Section modulus of the pipe139.23 cm³
Span limited by stress8.9195 m
Span limited by sag5.3239 m
Largest span (the smaller of the two)5.3239 m

Open this example in the calculator and change any input.

Formula

\(w = g\left[\rho_p \tfrac{\pi}{4}(D_o^2 - d_i^2) + \rho_f \tfrac{\pi}{4} d_i^2\right] + w_x\)

\(L_s = \sqrt{\frac{k_m Z S_b}{w}}, \quad L_d = \left(\frac{k_d E I y}{w}\right)^{1/4}, \quad L = \min(L_s, L_d)\)

\(k_m = 8,\ k_d = 384/5\ (\text{simply supported}); \quad k_m = 12,\ k_d = 384\ (\text{fixed})\)

Variables

Symbol Meaning SI unit
\(D_o\) Pipe outside diameter m
\(t\) Wall thickness (less corrosion allowance if you wish) m
\(\rho_p\) Pipe material density kg/m³
\(\rho_f\) Contents density (0 for gas) kg/m³
\(w_x\) Insulation, cladding and other weight per length N/m
\(E\) Modulus of elasticity Pa
\(S_b\) Allowed bending stress from weight (your design value) Pa
\(y\) Allowed sag at mid-span m
\(\text{ends}\) Treat the span as -
\(w\) Total weight per length N/m
\(I\) Second moment of area of the pipe m⁴
\(Z\) Section modulus of the pipe m³
\(L_s\) Span limited by stress m
\(L_d\) Span limited by sag m
\(L\) Largest span (the smaller of the two) m
\(d_i\) Pipe inside diameter m
\(g\) Standard gravity m/s²
\(k_m, k_d\) Beam coefficients for moment and sag -

Method and standards

The pipe is a uniformly loaded beam; the span is the smaller of the one that reaches the allowed bending stress and the one that reaches the allowed mid-span sag.

Where it is used

  • Laying out supports on racks and in plant rooms.
  • Checking spans after adding insulation or changing contents.
  • Quick checks where no code table applies.

Common mistakes

  • Forgetting the insulation and contents.
  • Using the same span next to valves and bends.
  • Ignoring the code's span table where it has one.

Assumptions and limits

  • Straight horizontal run, uniform weight.
  • Weight only: no wind, seismic or thermal loads.
  • A real continuous pipe lies between the simply supported and fixed-end cases; simply supported is the safe side. Concentrated loads (valves, flanges) are not included.

References

  • Beam theory for uniform load (simply supported and fixed-end)
  • Allowed stress and sag set by the designer

Questions and answers

What span suits a water-filled DN150 pipe?

With 100 N/m of insulation it weighs 560 N/m; 40 MPa bending allows 8.9 m but 2.5 mm sag allows only 5.3 m simply supported, so sag governs.

Why two limits?

Stress protects the pipe; sag keeps drainage and avoids pockets and vibration. Small pipes are usually sag-limited.

Simply supported or fixed?

A continuous pipe lies between the two; simply supported is the safe side.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.