FireCADCalc

Forklift Capacity at a Longer Load Centre

Reduced lifting capacity of a counterbalance forklift when the load centre is further out than rated, by moment balance about the front axle.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 3 t at 500 mm, load at 800 mm2.5 t at 600 mm, load at 900 mm

Results

Moment balance only: always use the maker's capacity plate, which also accounts for mast height, tilt and attachments.

Capacity at the actual load centre1,923.1kg
Derating76.923%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 t at 500 mm, load at 800 mm. The inputs, in the units selected above:

InputValue
Rated capacity3,000.0 kg
Rated load centre500.00 mm
Actual load centre800.00 mm
Front axle to fork face distance450.00 mm

Applying the formula below gives:

ResultValue
Capacity at the actual load centre2,280.0 kg
Derating76.000 %

Open this example in the calculator and change any input.

Formula

\(Q = \min\left(Q_r,\ Q_r\frac{a + c_r}{a + c}\right)\)

Variables

Symbol Meaning SI unit
\(Q_r\) Rated capacity kg
\(c_r\) Rated load centre m
\(c\) Actual load centre m
\(a\) Front axle to fork face distance m
\(Q\) Capacity at the actual load centre kg
\(Q/Q_r\) Derating -

Method and standards

Moment balance.

Where it is used

  • Handling long or bulky loads.
  • Choosing a truck size.

Common mistakes

  • Measuring the load centre from the heel of the forks only.
  • Ignoring attachments.

Assumptions and limits

  • Rigid truck on level ground. A load centre shorter than rated does not raise the capacity above Q_r.

References

  • Moment balance about the front axle (definitions)

Questions and answers

Why does capacity fall with load centre?

The truck's counterweight provides a fixed resisting moment about the front wheels; a load further out uses it up faster.

Is the plate value always lower?

Often yes, at full mast height; the plate governs.

What do the defaults represent?

A 3 t forklift rated at a 500 mm load centre carrying a load centred at 800 mm.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.