FireCADCalc

Fan Laws (Speed, Size and Density)

New flow, pressure and power of a fan when the speed, the wheel diameter or the gas density changes, by the fan similarity laws.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationThermic fluid heatingFan and blower

Inputs

Examples: Speed 980 to 740 rpmID fan gas 150 °C to 200 °C, same speedLarger wheel 10 % and speed 1 450 to 1 200 rpm

Known duty

New duty

Results

New volume flow19,827m³/h
New pressure rise38.732mmWC
New shaft power3.3471kW
Speed ratio0.82759
Density ratio0.91667

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Speed 980 to 740 rpm. The inputs, in the units selected above:

InputValue
Volume flow72,000 m³/h
Pressure rise305.91 mmWC
Shaft power75.000 kW
Speed980.00 rpm
Gas density1.2000 kg/m³
New speed740.00 rpm
Wheel diameter ratio (1 = same fan)1.0000 -
New gas density1.2000 kg/m³

Applying the formula below gives:

ResultValue
New volume flow54,367 m³/h
New pressure rise174.43 mmWC
New shaft power32.291 kW
Speed ratio0.75510
Density ratio1.0000

Open this example in the calculator and change any input.

Formula

\(\frac{\dot V_2}{\dot V_1} = \frac{N_2}{N_1}\left(\frac{D_2}{D_1}\right)^3 \qquad \frac{\Delta p_2}{\Delta p_1} = \frac{\rho_2}{\rho_1}\left(\frac{N_2}{N_1}\right)^2\left(\frac{D_2}{D_1}\right)^2 \qquad \frac{P_2}{P_1} = \frac{\rho_2}{\rho_1}\left(\frac{N_2}{N_1}\right)^3\left(\frac{D_2}{D_1}\right)^5\)

Variables

Symbol Meaning SI unit
\(\dot V_1\) known volume flow m³/s
\(\Delta p_1\) known pressure rise Pa
\(P_1\) known shaft power W
\(N_1\) known speed 1/s
\(\rho_1\) known gas density kg/m³
\(N_2\) new speed 1/s
\(D_2/D_1\) wheel diameter ratio of geometrically similar fans –
\(\rho_2\) new gas density kg/m³
\(\dot V_2\) new volume flow m³/s
\(\Delta p_2\) new pressure rise Pa
\(P_2\) new shaft power W
\(N_2/N_1\) speed ratio –
\(\rho_2/\rho_1\) density ratio –

Method and standards

The fan laws of AMCA Publication 99 and the similarity rules of ISO 5801, for geometrically similar fans at the same point of rating (same efficiency).

Where it is used

  • Predicting fan flow, pressure and power after speed changes.
  • VFD and inlet guide vane energy studies.
  • Correcting fan tests to design conditions.

Common mistakes

  • Ignoring density changes with temperature.
  • Applying the laws across very different speeds where efficiency changes.
  • Mixing static and total pressure.

Assumptions and limits

  • The fan stays at the same point of its curve: the system resistance must follow Δp ∝ ρ·V̇². A system with a fixed static component does not follow the laws along its own curve.
  • Efficiency is taken as constant; this holds for moderate changes (about −50 % to +20 % speed).
  • The diameter law applies to geometrically similar fans, not to a trimmed wheel in the same casing.
  • Compressibility and Reynolds-number effects are neglected.

References

  • AMCA Publication 99 (fan laws)
  • ISO 5801 (similarity)

Questions and answers

What are the three fan laws?

For one fan, flow varies with speed, pressure with speed squared and power with speed cubed. Slowing a fan from 980 to 740 rpm cuts flow to 75.5 %, pressure to 57 % and power to 43 %.

How does gas temperature affect a fan?

At constant speed the volume flow stays the same, while pressure and power fall in proportion to density. An ID fan handling gas at 200 °C instead of 150 °C develops 10.6 % less pressure and absorbs 10.6 % less power.

Why size the motor of an ID fan for cold gas?

At a cold start the gas is denser, so at the same speed and damper position the fan absorbs more power than at design temperature.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.