FireCADCalc

Hollomon–Jaffe Tempering Parameter and Equivalent Time

Hollomon–Jaffe tempering parameter of a temper or post-weld heat treatment from temperature and time, and the equivalent time at another temperature.

Thermal power plantRefinery and petrochemicalChemical and fertiliserBoiler

Inputs

Examples: 600 °C for 2 h, C 20, equivalent at 620 °C550 °C for 10 h, equivalent at 575 °CPWHT 680 °C for 1 h, equivalent at 700 °C

About 20 for carbon and low-alloy steels; use the value for your steel if known.

Results

Some sources state the parameter with T in °R or with time in seconds; compare values only in the same form.

Hollomon–Jaffe parameter T(C + log₁₀ t), T in K, t in h19,063
Time at T₂ for the same parameter0.38812h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 600 °C for 2 h, C 20, equivalent at 620 °C. The inputs, in the units selected above:

InputValue
Tempering temperature600.00 °C
Time at temperature2.0000 h
Material constant20.000 -
Other temperature for an equivalent treatment620.00 °C

Applying the formula below gives:

ResultValue
Hollomon–Jaffe parameter T(C + log₁₀ t), T in K, t in h17,726
Time at T₂ for the same parameter0.70216 h

Open this example in the calculator and change any input.

Formula

\(HP = T\,(C + \log_{10} t), \quad T\ \text{in K},\ t\ \text{in h}\)

\(t_2 = 10^{\,HP/T_2 - C}\)

Variables

Symbol Meaning SI unit
\(T\) Tempering temperature K
\(t\) Time at temperature s
\(C\) Material constant -
\(T_2\) Other temperature for an equivalent treatment K
\(HP\) Hollomon–Jaffe parameter T(C + log₁₀ t), T in K, t in h -
\(t_2\) Time at T₂ for the same parameter s

Method and standards

Hollomon and Jaffe showed that tempered hardness depends on the single parameter T(C + log t); equal parameters give equal tempering.

Where it is used

  • Comparing PWHT cycles on boiler and pressure parts.
  • Counting the effect of repeated PWHT on weld procedure qualification.
  • Planning heat treatment of forgings.

Common mistakes

  • Mixing °R and K forms, or hours and seconds.
  • Using C = 20 for steels where a different value is known.
  • Ignoring heating and cooling ramps.

Assumptions and limits

  • Isothermal hold; ramps not counted.

References

  • J.H. Hollomon and L.D. Jaffe (1945)
  • Trans. AIME 162

Questions and answers

What parameter does 600 °C for 2 h give?

With C = 20, HP = 873.15 × (20 + log 2) = 17 726 (about 17 730).

How long at 620 °C gives the same effect?

About 0.7 hours (42 minutes): each 20 K higher cuts the time by roughly a factor of three.

Why use it?

To compare tempering or PWHT cycles, and to add up repeated PWHT cycles on one weld.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.