Sound Power Level from Sound Pressure Level and Distance

Sound power level of a source from a measured sound pressure level at a distance with a directivity factor, and the level at another distance (free field).

Thermal power plantProcess steam and utilities

Inputs

Examples: Pump on a floor, 85 dB at 1 mFan in a corner, 92 dB at 3 m

Results

Free-field, far from the source; in rooms the reverberant field adds to these values.

Sound power level (dB re 1 pW)103.50
Sound power2.2406e-05kW
Sound pressure level at r₂ (dB)72.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Pump on a floor, 85 dB at 1 m. The inputs, in the units selected above:

InputValue
Measured sound pressure level (dB)85.000 -
Measurement distance1.0000 m
Directivity factor2: on a floor (hemisphere)
Distance for prediction10.000 m

Applying the formula below gives:

ResultValue
Sound power level (dB re 1 pW)92.982
Sound power1.9869e-06 kW
Sound pressure level at r₂ (dB)65.000

Open this example in the calculator and change any input.

Formula

\(L_W = L_p + 10\log_{10}\frac{4\pi r^2}{Q}, \quad W = 10^{-12}\cdot10^{L_W/10}, \quad L_{p2} = L_W - 10\log_{10}\frac{4\pi r_2^2}{Q}\)

Variables

Symbol Meaning SI unit
\(L_p\) Measured sound pressure level (dB) -
\(r\) Measurement distance m
\(Q\) Directivity factor -
\(r_2\) Distance for prediction m
\(L_W\) Sound power level (dB re 1 pW) -
\(W\) Sound power W
\(L_{p2}\) Sound pressure level at r₂ (dB) -

Method and standards

Free-field acoustics.

Where it is used

  • Noise limits for new equipment.
  • Plant boundary noise estimates.

Common mistakes

  • Measuring in the near field.
  • Ignoring room reflections.

Assumptions and limits

  • Point source, free field, uniform directivity: one measurement point stands for the whole surface. Survey methods (ISO 3744, ISO 3746) average several positions over a measurement surface; use them for declared values.
  • Measure in the far field: at 1 m from a large machine you may be in the near field, where the level does not fall as 1/r². The distance is not checked against the source size.

References

  • L_W = L_p + 10 log(4πr²/Q) (free-field point source)

Questions and answers

85 dB at 1 m from a pump on the floor?

L_W about 93.0 dB; about 65 dB at 10 m.

Why directivity?

A floor or wall reflects sound into a smaller solid angle.

Why does sound power matter?

It is a property of the machine; pressure depends on where you stand.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.