FireCADCalc

Single-Plane Balancing with a Trial Weight

Correction weight and angle for single-plane balancing from the original vibration, the vibration with a trial weight, and the trial weight (influence coefficients).

Thermal power plantProcess steam and utilities

Inputs

Examples: 8 mm/s at 30°, 5 mm/s at 110° with 20 g at 0°120 µm at 200°, 60 µm at 260° with 50 g at 90°4 mm/s at 0°, 9 mm/s at 0° with 10 g at 90° (wrong side)

In any unit (mm/s, µm); keep the same unit for both readings.

Results

Remove the trial weight before fitting the correction (or keep it and fit the vector difference). Angles are measured the same way as the phase readings: if the phase is measured against rotation and the weight angle with rotation (or the reverse), the correction angle comes out mirrored.

Effect of the trial weight (vector A₁ − A₀)103.92
Correction weight57.735g
Angle of the correction weight120.00°

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 mm/s at 30°, 5 mm/s at 110° with 20 g at 0°. The inputs, in the units selected above:

InputValue
Original vibration amplitude8.0000 -
Original phase30.000 °
Amplitude with the trial weight5.0000 -
Phase with the trial weight110.00 °
Trial weight20.000 g
Angle of the trial weight0 °

Applying the formula below gives:

ResultValue
Effect of the trial weight (vector A₁ − A₀)8.6665
Correction weight18.462 g
Angle of the correction weight34.623 °

Open this example in the calculator and change any input.

Formula

\(T = A_1 - A_0, \quad W_c = -\frac{A_0}{T}\, W_t \quad (\text{complex numbers})\)

Variables

Symbol Meaning SI unit
\(A_0\) Original vibration amplitude -
\(\phi_0\) Original phase rad
\(A_1\) Amplitude with the trial weight -
\(\phi_1\) Phase with the trial weight rad
\(m_t\) Trial weight kg
\(\theta_t\) Angle of the trial weight rad
\(|T|\) Effect of the trial weight (vector A₁ − A₀) -
\(m_c\) Correction weight kg
\(\theta_c\) Angle of the correction weight rad

Method and standards

Linear influence of unbalance on vibration.

Where it is used

  • Fan and pump balancing in the field.
  • Training.

Common mistakes

  • Leaving the trial weight on.
  • Inconsistent angle direction.

Assumptions and limits

  • Linear system, steady speed.
  • Phase readings and weight angles must use the same reference and the same direction (both with or both against rotation, and the same phase lag or lead convention as the instrument); a mismatch mirrors the correction angle.
  • The trial effect |T| should be a clear part of the original vibration; below 10 % of A₀ the page warns that the result is poorly conditioned.

References

  • Influence-coefficient (vector) method for single-plane balancing (Thearle 1934)

Questions and answers

What does the trial weight do?

Its effect (A₁ − A₀ as vectors) shows how much vibration a known weight makes, and at what angle.

How is the correction found?

Scale and turn the trial weight so its effect cancels the original vibration: W = −A₀/T × trial.

When is single-plane enough?

For narrow rotors such as fan wheels; long rotors need two planes.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.