FireCADCalc

A-Weighted Sound Level from Octave-Band Levels

Overall A-weighted and unweighted sound pressure levels from octave-band levels at 63 Hz to 8 kHz, with the dominant band after weighting.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Fan-room spectrumCompressor house, high-frequency

Results

A-weighting corrections at octave centres: −26.2, −16.1, −8.6, −3.2, 0, +1.2, +1.0, −1.1 dB (IEC 61672 values). The dominant A-weighted band shows where noise control will pay off most.

A-weighted level (dBA)87.009
Unweighted (linear) level (dB)92.732
Dominant band after A-weighting1,000.0Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Fan-room spectrum. The inputs, in the units selected above:

InputValue
63 Hz band (dB)85.000 -
125 Hz band (dB)88.000 -
250 Hz band (dB)86.000 -
500 Hz band (dB)84.000 -
1 kHz band (dB)82.000 -
2 kHz band (dB)79.000 -
4 kHz band (dB)75.000 -
8 kHz band (dB)70.000 -

Applying the formula below gives:

ResultValue
A-weighted level (dBA)87.009
Unweighted (linear) level (dB)92.732
Dominant band after A-weighting1,000.0 Hz

Open this example in the calculator and change any input.

Formula

\(L_A = 10\log_{10}\sum_i10^{(L_i + A_i)/10}, \quad L_Z = 10\log_{10}\sum_i10^{L_i/10}\)

Variables

Symbol Meaning SI unit
\(L_{63}\) 63 Hz band (dB) -
\(L_{125}\) 125 Hz band (dB) -
\(L_{250}\) 250 Hz band (dB) -
\(L_{500}\) 500 Hz band (dB) -
\(L_{1k}\) 1 kHz band (dB) -
\(L_{2k}\) 2 kHz band (dB) -
\(L_{4k}\) 4 kHz band (dB) -
\(L_{8k}\) 8 kHz band (dB) -
\(L_A\) A-weighted level (dBA) -
\(L_Z\) Unweighted (linear) level (dB) -
\(f_{dom}\) Dominant band after A-weighting 1/s

Method and standards

Logarithmic addition with A-weighting.

Where it is used

  • Noise surveys and specifications.
  • Choosing where to treat noise.

Common mistakes

  • Adding decibels arithmetically.
  • Using one-third-octave weights for octave bands.

Assumptions and limits

  • Octave bands 63 Hz–8 kHz.

References

  • A-weighting at octave-band centre frequencies (IEC 61672-1 values) and logarithmic addition

Questions and answers

Why A-weighting?

The ear is less sensitive at low frequencies; dBA approximates how loud noise sounds and how it harms hearing.

Why can dBA be much lower than dB?

Low-frequency noise from fans, engines and furnaces is heavily discounted by A-weighting.

What do the defaults represent?

A fan-room spectrum peaking at 125 Hz.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.