Worked example
Example: Fan-room spectrum. The inputs, in the units selected above:
| Input | Value |
|---|---|
| 63 Hz band (dB) | 85.000 - |
| 125 Hz band (dB) | 88.000 - |
| 250 Hz band (dB) | 86.000 - |
| 500 Hz band (dB) | 84.000 - |
| 1 kHz band (dB) | 82.000 - |
| 2 kHz band (dB) | 79.000 - |
| 4 kHz band (dB) | 75.000 - |
| 8 kHz band (dB) | 70.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| A-weighted level (dBA) | 87.009 |
| Unweighted (linear) level (dB) | 92.732 |
| Dominant band after A-weighting | 1,000.0 Hz |
Open this example in the calculator and change any input.
Formula
\(L_A = 10\log_{10}\sum_i10^{(L_i + A_i)/10}, \quad L_Z = 10\log_{10}\sum_i10^{L_i/10}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_{63}\) | 63 Hz band (dB) | - |
| \(L_{125}\) | 125 Hz band (dB) | - |
| \(L_{250}\) | 250 Hz band (dB) | - |
| \(L_{500}\) | 500 Hz band (dB) | - |
| \(L_{1k}\) | 1 kHz band (dB) | - |
| \(L_{2k}\) | 2 kHz band (dB) | - |
| \(L_{4k}\) | 4 kHz band (dB) | - |
| \(L_{8k}\) | 8 kHz band (dB) | - |
| \(L_A\) | A-weighted level (dBA) | - |
| \(L_Z\) | Unweighted (linear) level (dB) | - |
| \(f_{dom}\) | Dominant band after A-weighting | 1/s |
Method and standards
Logarithmic addition with A-weighting.
Where it is used
- Noise surveys and specifications.
- Choosing where to treat noise.
Common mistakes
- Adding decibels arithmetically.
- Using one-third-octave weights for octave bands.
Assumptions and limits
- Octave bands 63 Hz–8 kHz.
References
- A-weighting at octave-band centre frequencies (IEC 61672-1 values) and logarithmic addition
Questions and answers
Why A-weighting?
The ear is less sensitive at low frequencies; dBA approximates how loud noise sounds and how it harms hearing.
Why can dBA be much lower than dB?
Low-frequency noise from fans, engines and furnaces is heavily discounted by A-weighting.
What do the defaults represent?
A fan-room spectrum peaking at 125 Hz.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.