Worked example
Example: 4 m wall, 5 m from source, receiver 20 m, 500 Hz. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Source height | 1.0000 m |
| Barrier height | 4.0000 m |
| Receiver height | 1.5000 m |
| Source to barrier distance | 5.0000 m |
| Barrier to receiver distance | 20.000 m |
| Frequency | 500.00 Hz |
Applying the formula below gives:
| Result | Value |
|---|---|
| Path difference | 0.98160 m |
| Fresnel number | 2.8618 |
| Barrier attenuation (dB) | 17.799 |
Open this example in the calculator and change any input.
Formula
\(\delta = a + b - d, \quad N = \frac{2\delta}{\lambda}, \quad IL = 10\log_{10}(3 + 20N)\ \le 20\ \mathrm{dB}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h_s\) | Source height | m |
| \(h_b\) | Barrier height | m |
| \(h_r\) | Receiver height | m |
| \(d_s\) | Source to barrier distance | m |
| \(d_r\) | Barrier to receiver distance | m |
| \(f\) | Frequency | 1/s |
| \(\delta\) | Path difference | m |
| \(N\) | Fresnel number | - |
| \(IL\) | Barrier attenuation (dB) | - |
Method and standards
Maekawa's barrier chart, approximated by 10 log₁₀(3 + 20N).
Where it is used
- Plant boundary noise control.
- Shielding DG sets and cooling towers.
Common mistakes
- Ignoring flanking around the ends.
- Expecting large attenuation at low frequency.
Assumptions and limits
- Infinite thin barrier; point source; speed of sound 343 m/s (air at 20 °C), so λ = 343/f.
- When the receiver sees the source over the barrier (illuminated zone) the attenuation is taken as 0 dB and N is shown with a negative sign; the chart's small attenuation near grazing (up to about 5 dB at N = 0) is not modelled, so results just below the line of sight jump from 0 to about 4.8 dB.
References
- Maekawa (1968) barrier chart approximated by IL = 10 log₁₀(3 + 20N)
- the single-edge form also used in ISO 9613-2
- capped at 20 dB
Questions and answers
Why do barriers work better at high frequency?
Short wavelengths diffract less over the top; the Fresnel number grows with frequency.
How tall should a barrier be?
Tall enough to break the line of sight with a good margin, and close to either the source or the receiver.
What do the defaults represent?
A 4 m wall 5 m from a 1 m high source, receiver 20 m beyond at 1.5 m, at 500 Hz.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.