FireCADCalc

Noise Barrier Attenuation (Maekawa Fresnel Number)

Attenuation of a thin noise barrier from source, barrier and receiver geometry and frequency, via path difference and Fresnel number.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 4 m wall, 5 m from source, receiver 20 m, 500 Hz3 m wall at 2 kHz, close to receiver

Results

Thin barrier, point source, no ground effect; practical barriers rarely give more than 15–20 dB. Treat each octave band separately.

Path difference0.36698m
Fresnel number4.2796
Barrier attenuation (dB)19.474

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 4 m wall, 5 m from source, receiver 20 m, 500 Hz. The inputs, in the units selected above:

InputValue
Source height1.0000 m
Barrier height4.0000 m
Receiver height1.5000 m
Source to barrier distance5.0000 m
Barrier to receiver distance20.000 m
Frequency500.00 Hz

Applying the formula below gives:

ResultValue
Path difference0.98160 m
Fresnel number2.8618
Barrier attenuation (dB)17.799

Open this example in the calculator and change any input.

Formula

\(\delta = a + b - d, \quad N = \frac{2\delta}{\lambda}, \quad IL = 10\log_{10}(3 + 20N)\ \le 20\ \mathrm{dB}\)

Variables

Symbol Meaning SI unit
\(h_s\) Source height m
\(h_b\) Barrier height m
\(h_r\) Receiver height m
\(d_s\) Source to barrier distance m
\(d_r\) Barrier to receiver distance m
\(f\) Frequency 1/s
\(\delta\) Path difference m
\(N\) Fresnel number -
\(IL\) Barrier attenuation (dB) -

Method and standards

Maekawa's barrier chart, approximated by 10 log₁₀(3 + 20N).

Where it is used

  • Plant boundary noise control.
  • Shielding DG sets and cooling towers.

Common mistakes

  • Ignoring flanking around the ends.
  • Expecting large attenuation at low frequency.

Assumptions and limits

  • Infinite thin barrier; point source; speed of sound 343 m/s (air at 20 °C), so λ = 343/f.
  • When the receiver sees the source over the barrier (illuminated zone) the attenuation is taken as 0 dB and N is shown with a negative sign; the chart's small attenuation near grazing (up to about 5 dB at N = 0) is not modelled, so results just below the line of sight jump from 0 to about 4.8 dB.

References

  • Maekawa (1968) barrier chart approximated by IL = 10 log₁₀(3 + 20N)
  • the single-edge form also used in ISO 9613-2
  • capped at 20 dB

Questions and answers

Why do barriers work better at high frequency?

Short wavelengths diffract less over the top; the Fresnel number grows with frequency.

How tall should a barrier be?

Tall enough to break the line of sight with a good margin, and close to either the source or the receiver.

What do the defaults represent?

A 4 m wall 5 m from a 1 m high source, receiver 20 m beyond at 1.5 m, at 500 Hz.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.