FireCADCalc

Hydrostatic Tank Gauging: Mass, Density and Level

Liquid mass, density and level in a vertical tank from bottom, middle and top pressure transmitters (hydrostatic tank gauging), for constant cross-section tanks.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 50 m² tank, transmitters 2 m apartEthanol tank 120 m², 3 m apart

Results

Mass follows directly from the pressure difference times area, without knowing density: the strength of HTG for custody and inventory. The middle transmitter must be covered for density to be valid.

Liquid density791.98kg/m³
Liquid mass above the bottom transmitter709.72t
Liquid level above tank floor7.7678m
Liquid volume above the bottom transmitter896.14m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 m² tank, transmitters 2 m apart. The inputs, in the units selected above:

InputValue
Bottom transmitter (absolute or gauge, same basis)1.8500 bar
Middle transmitter1.6900 bar
Top (vapour space) transmitter1.0000 bar
Vertical distance bottom to middle transmitter2.0000 m
Tank cross-section area50.000 m²
Bottom transmitter height above tank floor0.20000 m

Applying the formula below gives:

ResultValue
Liquid density815.77 kg/m³
Liquid mass above the bottom transmitter433.38 t
Liquid level above tank floor10.825 m
Liquid volume above the bottom transmitter531.25 m³

Open this example in the calculator and change any input.

Formula

\(\rho = \frac{p_b - p_m}{gh_{bm}}, \quad M = \frac{A(p_b - p_t)}{g}, \quad L = \frac{p_b - p_t}{\rho g} + z_b\)

Variables

Symbol Meaning SI unit
\(p_b\) Bottom transmitter (absolute or gauge, same basis) Pa
\(p_m\) Middle transmitter Pa
\(p_t\) Top (vapour space) transmitter Pa
\(h_{bm}\) Vertical distance bottom to middle transmitter m
\(A\) Tank cross-section area m²
\(z_b\) Bottom transmitter height above tank floor m
\(\rho\) Liquid density kg/m³
\(M\) Liquid mass above the bottom transmitter kg
\(L\) Liquid level above tank floor m
\(V\) Liquid volume above the bottom transmitter m³

Method and standards

Hydrostatics.

Where it is used

  • Ethanol, molasses and fuel tank inventory.
  • Custody transfer support.

Common mistakes

  • Middle transmitter uncovered.
  • Mixing gauge and absolute transmitters.

Assumptions and limits

  • Uniform density; vertical-wall tank; the middle transmitter covered by liquid (otherwise the page reports failure).
  • Standard gravity; custody-transfer HTG (API MPMS 3.6) uses local gravity, which changes the mass by up to about 0.3 %.

References

  • Hydrostatic tank gauging (Lipták, Instrument Engineers' Handbook, 4th ed. (CRC Press), vol. 1; API MPMS ch. 3.6 principle)

Questions and answers

Why measure mass by pressure?

The bottom pressure is the weight of the liquid column per unit area: mass = AΔp/g, whatever the temperature or density.

What does the middle transmitter add?

Density, from the pressure difference over a known height, and from that level and volume.

What do the defaults represent?

A 50 m² tank with transmitters 2 m apart.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.