Worked example
Example: 60 mm x 1 m, 5 kg, oil 850, 0.4 m covered. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Displacer diameter | 60.000 mm |
| Displacer length (measuring range) | 1.0000 m |
| Displacer mass | 5.0000 kg |
| Liquid density | 850.00 kg/m³ |
| Vapour density above the liquid | 1.2000 kg/m³ |
| Level on the displacer (from its bottom) | 0.40000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Buoyancy at the level | 9.4474 N |
| Apparent weight at the level | 39.586 N |
| Force change over the full range | 23.535 N |
| Level as a share of the range | 40.000 % |
Open this example in the calculator and change any input.
Formula
\(F_b = g A [\rho h + \rho_v (L - h)], \quad W_a = m g - F_b, \quad \Delta F = g A L (\rho - \rho_v)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d\) | Displacer diameter | m |
| \(L\) | Displacer length (measuring range) | m |
| \(m\) | Displacer mass | kg |
| \(\rho\) | Liquid density | kg/m³ |
| \(\rho_v\) | Vapour density above the liquid | kg/m³ |
| \(h\) | Level on the displacer (from its bottom) | m |
| \(F_b\) | Buoyancy at the level | N |
| \(W_a\) | Apparent weight at the level | N |
| \(\Delta F\) | Force change over the full range | N |
| \(h/L\) | Level as a share of the range | - |
Method and standards
Archimedes' principle.
Where it is used
- Level control in drums, separators and condensers.
- Calibration with water.
Common mistakes
- Ignoring vapour density at high pressure.
- Wrong liquid density.
Assumptions and limits
- Vertical cylindrical displacer; liquid denser than the vapour.
- A negative apparent weight (the displacer would float) is flagged.
References
- Archimedes' principle
Questions and answers
What force change does a 60 mm × 1 m displacer give in 850 kg/m³ oil?
23.5 N over the range.
Why does density matter?
Buoyancy is density × displaced volume, so a lighter liquid reads low.
Can displacers measure interface?
Yes, fully submerged, by the density difference of the two liquids.