FireCADCalc

Analyser Sample Line Transport Lag

Time for a gas or liquid sample to travel from the tap to the analyser through the sample line, from line size, length, flow and pressure.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 40 m of 4 mm line, 2 L/min gas, 0.2 L filtersGas at 3 bar(a): 30 m of 6 mm, 5 L/minWater sample: 50 m of 10 mm, 1 L/min

Results

Plug flow; the analyser's own response time is added on top. Gas is compressed at line pressure, so higher pressure means a longer lag.

Line and component volume1.3482L
Transport lag47.902s
Velocity in the line0.99546m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 m of 4 mm line, 2 L/min gas, 0.2 L filters. The inputs, in the units selected above:

InputValue
Sample line length40.000 m
Inside diameter of the line4.0000 mm
Sample flow (at the analyser, atmospheric)2.0000 L/min
Mean pressure in the line (absolute)1.0132 bar
Other volumes (filters, coolers)0.20000 L
SampleGas

Applying the formula below gives:

ResultValue
Line and component volume0.70265 L
Transport lag21.080 s
Velocity in the line2.6526 m/s

Open this example in the calculator and change any input.

Formula

\(V = \frac{\pi d^2}{4} L + V_x, \quad t_d = \frac{V}{Q\,(p_{atm}/p)}\)

Variables

Symbol Meaning SI unit
\(L\) Sample line length m
\(d\) Inside diameter of the line m
\(Q_N\) Sample flow (at the analyser, atmospheric) m³/s
\(p\) Mean pressure in the line (absolute) Pa
\(V_x\) Other volumes (filters, coolers) m³
\(\text{fluid}\) Sample -
\(V\) Line and component volume m³
\(t_d\) Transport lag s
\(v\) Velocity in the line m/s

Method and standards

Residence time of plug flow.

Where it is used

  • Combustion and emission analysers.
  • Control loops on analyser signals.

Common mistakes

  • Forgetting coolers and filters.
  • Using line flow at the wrong pressure.

Assumptions and limits

  • Plug flow, no mixing.
  • The gas flow is corrected for pressure only. In a heated line (for example a 180 °C CEMS line) the gas is also expanded by temperature, so the real velocity is higher and the lag shorter than computed.

References

  • Plug-flow residence time t = V / Q (ideal gas at line pressure)

Questions and answers

How long for 40 m of 4 mm line at 2 L/min?

21 s with 0.2 L of filters.

How to cut the lag?

Smaller line, a fast loop or a bypass, and the analyser close to the tap.

Why does pressure matter for gas?

At higher pressure more gas fills the line for the same atmospheric flow.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...