Asphalt Mix Volumetrics: Air Voids, VMA, VFB and Effective Binder

Air voids, voids in mineral aggregate, voids filled with binder, effective aggregate specific gravity and absorbed and effective binder of a compacted asphalt mix.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative dense mix, 5 % binderAbsorptive aggregate, 6 % binderBase course 4.2 %

Accepted: 1.8 to 2.8
Accepted: 2 to 3
Accepted: 2.2 to 3.2
Accepted: 0.95 to 1.1
Accepted: 2 to 10 %

Results

V_a = (G_mm − G_mb)/G_mm; VMA = 1 − G_mbP_s/G_sb; VFB = (VMA − V_a)/VMA; G_se = P_s/(1/G_mm − P_b/G_b); P_ba = G_b(G_se − G_sb)/(G_sbG_se); P_be = P_b − P_baP_s. Typical design targets are about 4 % air voids with VMA and VFB inside the user's specification band for the aggregate size.

Air voids4.0816%
Voids in mineral aggregate15.755%
Voids filled with binder74.093%
Effective specific gravity of aggregate2.6452
Absorbed binder (by aggregate)-0.070121%
Effective binder (by mix)5.0666%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative dense mix, 5 % binder. The inputs, in the units selected above:

InputValue
Bulk specific gravity of compacted mix2.3500 -
Maximum specific gravity of mix2.4500 -
Bulk specific gravity of aggregate2.6500 -
Binder specific gravity1.0200 -
Binder content (by total mix)5.0000 %

Applying the formula below gives:

ResultValue
Air voids4.0816 %
Voids in mineral aggregate15.755 %
Voids filled with binder74.093 %
Effective specific gravity of aggregate2.6452
Absorbed binder (by aggregate)-0.070121 %
Effective binder (by mix)5.0666 %

Open this example in the calculator and change any input.

Formula

\(V_a = \frac{G_{mm} - G_{mb}}{G_{mm}}, \quad VMA = 1 - \frac{G_{mb}P_s}{G_{sb}}, \quad VFB = \frac{VMA - V_a}{VMA}\)

Variables

Symbol Meaning SI unit
\(G_{mb}\) Bulk specific gravity of compacted mix -
\(G_{mm}\) Maximum specific gravity of mix -
\(G_{sb}\) Bulk specific gravity of aggregate -
\(G_b\) Binder specific gravity -
\(P_b\) Binder content (by total mix) -
\(V_a\) Air voids -
\(VMA\) Voids in mineral aggregate -
\(VFB\) Voids filled with binder -
\(G_{se}\) Effective specific gravity of aggregate -
\(P_{ba}\) Absorbed binder (by aggregate) -
\(P_{be}\) Effective binder (by mix) -

Method and standards

Mix volumetrics.

Where it is used

  • Bituminous mix design and plant control.
  • Checking cores from laid pavement.

Common mistakes

  • Using apparent instead of bulk aggregate gravity for VMA.
  • Mixing binder by mix and by aggregate.

Assumptions and limits

  • Consistent specific gravities from standard tests.

References

  • Asphalt mix volumetric relations

Questions and answers

Why does absorbed binder matter?

Binder soaked into aggregate pores does nothing for coating or durability; only effective binder does.

What do low air voids mean?

Below about 3 % the mix risks bleeding and rutting; above about 6 % it ages and lets water in.

What do the defaults represent?

An illustrative dense mix: G_mb 2.35, G_mm 2.45, G_sb 2.65, G_b 1.02 and 5 % binder.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Asphalt Institute, MS-2 Asphalt Mix Design Methods, 7th ed. (2014)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.