FireCADCalc

Detonation Pressure, Load Factor and Strengths of an Explosive

Detonation pressure from density and velocity of detonation, load factor of a column, and absolute and relative weight and bulk strengths against ANFO.

Inputs

Examples: Packaged emulsion SG 1.2, 16,000 ft/s, 5 in, 750 cal/gANFO SG 0.85, 12,000 ft/s, 6.75 in, 912 cal/gPentolite booster SG 1.6, 24,000 ft/s, 3 in, 1,250 cal/g

Accepted: 0.3 to 2
Accepted: 3,280.8 to 29,528 ft/s
Accepted: 0.3937 to 19.685 in
Accepted: 238.85 to 1,910.8 kcal/kg

Results

Detonation pressure, not energy, decides how well a charge initiates the next: a primer or booster should have a higher detonation pressure than the column it fires. ANFO's 912 cal/g and 739 cal/cc are the reference strengths.

Detonation pressure214.05kbar
Load factor4.9031lb/ft
Absolute bulk strength8,373,600kJ/Nm³
Relative weight strength (ANFO = 100)137.06
Relative bulk strength (ANFO = 100)270.64

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Packaged emulsion SG 1.2, 16,000 ft/s, 5 in, 750 cal/g. The inputs, in the units selected above:

InputValue
Explosive specific gravity1.2000 -
Detonation velocity16,000 ft/s
Explosive column diameter5.0000 in
Absolute weight strength750.00 kcal/kg

Applying the formula below gives:

ResultValue
Detonation pressure71.350 kbar
Load factor10.215 lb/ft
Absolute bulk strength3,768,120 kJ/Nm³
Relative weight strength (ANFO = 100)82.237
Relative bulk strength (ANFO = 100)121.79

Open this example in the calculator and change any input.

Formula

\(P = \frac{\rho D^2}{4}\ \left(= 2.32\times10^{-7}\rho D^2\ \text{kbar, }D\text{ in ft/s}\right)\)

\(LF = 0.34\,\rho d^2, \quad ABS = AWS\,\rho, \quad RWS = \frac{AWS}{912}, \quad RBS = \frac{ABS}{739}\)

Variables

Symbol Meaning SI unit
\(\rho\) Explosive specific gravity -
\(D\) Detonation velocity m/s
\(d\) Explosive column diameter m
\(AWS\) Absolute weight strength J/kg
\(P\) Detonation pressure Pa
\(LF\) Load factor kg/m
\(ABS\) Absolute bulk strength J/m³
\(RWS\) Relative weight strength (ANFO = 100) -
\(RBS\) Relative bulk strength (ANFO = 100) -

Method and standards

Chapman-Jouguet detonation pressure and explosive strength ratios.

Where it is used

  • Choosing primers and boosters.
  • Comparing explosive products.

Common mistakes

  • Using the unconfined velocity for a confined column.
  • Comparing weight strengths when the hole volume is fixed.

Assumptions and limits

  • Ideal detonation; velocity depends on charge diameter and confinement.

Questions and answers

Why is the pressure ρD²/4?

It is the Chapman-Jouguet pressure for detonation products with an expansion exponent of 3; Designers write it as 2.32 × 10⁻⁷ ρD² kbar with D in ft/s.

What is the difference between weight and bulk strength?

Weight strength is energy per mass; bulk strength is energy per volume of hole, so a dense explosive has a higher bulk strength for the same weight strength.

What do the defaults represent?

A packaged emulsion of SG 1.2 at 16,000 ft/s and 750 cal/g in a 5 in column: 71 kbar, 10.2 lb/ft, RWS 82 and RBS 122 against ANFO.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Dougherty and Schissler (eds.), SME Mining Reference Handbook, 2nd ed. (SME, 2020), ch. 11, eqs. 11.37-11.39 and 11.49-11.50

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.