Worked example
Example: Blasted rock 2.65 to 1.77 t/m3, 1,000 BCM. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bank density | 2,650.0 kg/m³ |
| Loose density | 1,770.0 kg/m³ |
| Bank volume | 1,000.0 m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Swell | 49.718 % |
| Swell factor (bank per loose) | 0.66792 |
| Loose volume | 1,497.2 m³ |
| Mass | 2,650.0 t |
Open this example in the calculator and change any input.
Formula
\(\text{swell} = \frac{BD}{LD} - 1, \quad SF = \frac{1}{1 + \text{swell}} = \frac{LD}{BD}, \quad V_l = V_b(1 + \text{swell})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(BD\) | Bank density | kg/m³ |
| \(LD\) | Loose density | kg/m³ |
| \(V_b\) | Bank volume | m³ |
| \(\text{swell}\) | Swell | - |
| \(SF\) | Swell factor (bank per loose) | - |
| \(V_l\) | Loose volume | m³ |
| \(m\) | Mass | kg |
Method and standards
Bank and loose volume relations.
Where it is used
- Converting bucket and truck capacities to production.
- Dump and stockpile volumes.
Common mistakes
- Multiplying by the swell when dividing is meant.
- Using compacted density for loose.
Assumptions and limits
- Densities are averages for the material.
Questions and answers
Is the swell factor the same as percent swell?
No: percent swell is how much the volume grows (bank to loose); the swell factor is the ratio of bank to loose volume, 1/(1 + swell).
What swell is typical?
Blasted hard rock swells 50-70 %, clay and earth 25-40 %, sand and gravel 10-15 %.
What do the defaults represent?
Rock of 2,650 kg/m³ in place and 1,770 kg/m³ loose: 49.7 % swell, swell factor 0.668, so 1,000 BCM becomes 1,497 LCM weighing 2,650 t.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Dougherty and Schissler (eds.), SME Mining Reference Handbook, 2nd ed. (SME, 2020), ch. 12, eqs. 12.10-12.13