Electric Blasting Circuit: Resistance and Firing Current

Resistance of electric detonators in series, parallel or series-in-parallel with the lead wire, and the current from a blasting machine of given voltage.

Inputs

Examples: 40 caps of 1.6 ohm, 2 series, 500 ft at 2.6 ohm/1000 ft, 450 VStraight series 20 caps, 300 ft, 150 V90 caps in 3 series, 1,000 ft, 900 V

Accepted: 1 to 2,000
Accepted: 1 to 200
Accepted: 0.1 to 20 Ω
Accepted: 0 to 16,404 ft
Accepted: 0 to 100 Ω
Accepted: 1 to 5,000 V

Results

Series resistances add and equal parallel branches divide; balance the series so each carries the same current. Compare the current per detonator with the manufacturer's recommended firing current, and test the circuit with a blasting galvanometer, not an ordinary meter.

Resistance of one series40.000Ω
Resistance of the detonator network40.000Ω
Wire resistance0.96000Ω
Total circuit resistance40.960Ω
Total current3.6621A
Current through each detonator3.6621A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 caps of 1.6 ohm, 2 series, 500 ft at 2.6 ohm/1000 ft, 450 V. The inputs, in the units selected above:

InputValue
Number of detonators40.000 -
Number of parallel series (1 = straight series)2.0000 -
Resistance of one detonator with its legwires1.6000 Ω
Lead and connecting wire length (both conductors)500.00 ft
Wire resistance per 1,000 ft2.6000 Ω
Blasting machine voltage450.00 V

Applying the formula below gives:

ResultValue
Resistance of one series32.000 Ω
Resistance of the detonator network16.000 Ω
Wire resistance1.3000 Ω
Total circuit resistance17.300 Ω
Total current26.012 A
Current through each detonator13.006 A

Open this example in the calculator and change any input.

Formula

\(R_s = \frac{n}{p}R, \quad R_c = \frac{R_s}{p}, \quad R_w = \frac{L\,R_{1000}}{1000}, \quad I = \frac{V}{R_c + R_w}, \quad I_d = \frac{I}{p}\)

Variables

Symbol Meaning SI unit
\(n\) Number of detonators -
\(p\) Number of parallel series (1 = straight series) -
\(R\) Resistance of one detonator with its legwires Ω
\(L\) Lead and connecting wire length (both conductors) m
\(R_{1000}\) Wire resistance per 1,000 ft Ω
\(V\) Blasting machine voltage V
\(R_s\) Resistance of one series Ω
\(R_c\) Resistance of the detonator network Ω
\(R_w\) Wire resistance Ω
\(R_{total}\) Total circuit resistance Ω
\(I\) Total current A
\(I_d\) Current through each detonator A

Method and standards

Series and parallel resistance (Ohm's law).

Where it is used

  • Checking a blasting machine against the circuit.
  • Designing series-in-parallel hook-ups.

Common mistakes

  • Counting one conductor of the lead line instead of both.
  • Unequal numbers of detonators in each series.

Assumptions and limits

  • Resistive circuit; capacitor-discharge machines deliver a pulse, so compare with the maker's rating.

Questions and answers

Why use series-in-parallel?

One long series needs a high voltage; splitting it into equal parallel series lowers the resistance so a smaller machine can fire it, provided each series gets enough current.

Why must the series be balanced?

Unequal series take unequal currents and the one with least current may misfire.

What do the defaults represent?

40 detonators of 1.6 Ω in 2 parallel series of 20, with 500 ft of wire at 2.6 Ω per 1,000 ft, on a 450 V machine: 32 Ω per series and 16.0 Ω for the network, 1.3 Ω of wire, 26 A in total and 13 A in each series.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Dougherty and Schissler (eds.), SME Mining Reference Handbook, 2nd ed. (SME, 2020), ch. 11, eqs. 11.46-11.48 (ISEE Blasters' Handbook)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.