FireCADCalc

Shallow Footing Bearing Capacity (General Equation, Vesić Factors)

Ultimate and safe bearing capacity of a strip, square, circular or rectangular footing from soil strength, depth and width, with Vesić factors and De Beer shape factors.

Inputs

Examples: Square 2 m footing, 1.5 m deep, sand 30°Strip 1.2 m in clay, c 50 kPa, phi 0Rectangle 2 x 3 m, 2 m deep, phi 25°, c 10 kPaCircular 3 m, 1.5 m deep, sand 35°Square 2 m, water table at the baseSquare 2 m, water table 0.5 m above the baseSquare 2 m, water table 1 m below the base

Leave at 100 m when the water table is deep. Below it the soil is taken as saturated at the bulk density entered, with submerged weight (ρ − 1000) g.

Results

General shear failure, vertical central load, level ground; depth factors are left out (conservative). Settlement often governs: check it separately.

Bearing capacity factor N_c20.721
Bearing capacity factor N_q10.662
Bearing capacity factor N_γ10.876
Effective overburden pressure at the base37.265kPa
Ultimate bearing capacity947.74kPa
Safe bearing capacity (gross, q_u / F_s)379.10kPa
Net safe bearing capacity (q_u − q)/F_s364.19kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Square 2 m footing, 1.5 m deep, sand 30°. The inputs, in the units selected above:

InputValue
FootingSquare
Width (or diameter)2.0000 m
Length (rectangular footing)3.0000 m
Depth of the base below ground1.5000 m
Bulk density of the soil1,800.0 kg/m³
Angle of internal friction30.000 °
Cohesion0 kPa
Factor of safety3.0000 -
Depth of the water table below ground100.00 m

Applying the formula below gives:

ResultValue
Bearing capacity factor N_c30.140
Bearing capacity factor N_q18.401
Bearing capacity factor N_γ22.402
Effective overburden pressure at the base26.478 kPa
Ultimate bearing capacity1,005.8 kPa
Safe bearing capacity (gross, q_u / F_s)335.26 kPa
Net safe bearing capacity (q_u − q)/F_s326.44 kPa

Open this example in the calculator and change any input.

Formula

\(q_u = c N_c F_{cs} + q N_q F_{qs} + \tfrac12 \gamma B N_\gamma F_{\gamma s}\)

Water table at depth \(D_w\), with \(\gamma = \rho g\) and \(\gamma' = (\rho - \rho_w) g\) (Das):

\(D_w \le D_f:\ q = \gamma D_w + \gamma'(D_f - D_w),\ \gamma \to \gamma'; \quad D_f < D_w < D_f + B:\ q = \gamma D_f,\ \gamma \to \gamma' + \frac{D_w - D_f}{B}(\gamma - \gamma'); \quad D_w \ge D_f + B:\ \text{no effect}\)

\(N_q = e^{\pi \tan\varphi} \tan^2\left(45° + \frac{\varphi}{2}\right), \quad N_c = (N_q - 1)\cot\varphi, \quad N_\gamma = 2 (N_q + 1) \tan\varphi\)

\(F_{cs} = 1 + \frac{B}{L}\frac{N_q}{N_c}, \quad F_{qs} = 1 + \frac{B}{L}\tan\varphi, \quad F_{\gamma s} = 1 - 0.4\frac{B}{L}\)

Variables

Symbol Meaning SI unit
\(\text{shape}\) Footing -
\(B\) Width (or diameter) m
\(L\) Length (rectangular footing) m
\(D_f\) Depth of the base below ground m
\(\rho\) Bulk density of the soil kg/m³
\(\varphi\) Angle of internal friction rad
\(c\) Cohesion Pa
\(F_s\) Factor of safety -
\(D_w\) Depth of the water table below ground m
\(\gamma, \gamma'\) Bulk and submerged unit weight N/m³
\(\rho_w\) Density of water, 1000 kg/m³
\(N_c\) Bearing capacity factor N_c -
\(N_q\) Bearing capacity factor N_q -
\(N_\gamma\) Bearing capacity factor N_γ -
\(q\) Effective overburden pressure at the base Pa
\(q_u\) Ultimate bearing capacity Pa
\(q_a\) Safe bearing capacity (gross, q_u / F_s) Pa
\(q_{ns}\) Net safe bearing capacity (q_u − q)/F_s Pa
\(g\) Standard gravity m/s²
\(F_{cs}, F_{qs}, F_{\gamma s}\) Shape factors -

Method and standards

The general bearing capacity equation with Prandtl–Reissner N_c and N_q, Vesić's N_γ and De Beer's shape factors as given by Das; depth and inclination factors are left out, which is conservative.

Where it is used

  • Sizing footings for equipment, pipe racks and small buildings.
  • Checking a soil report's safe bearing capacity.
  • Comparing footing widths and depths.

Common mistakes

  • Using total instead of effective unit weight below the water table.
  • Treating safe bearing capacity as allowable without a settlement check.
  • Mixing factors from different methods.

Assumptions and limits

  • General shear failure; vertical, central load; level ground. The factors are Prandtl–Reissner N_c and N_q, Vesić N_γ and De Beer shape factors in Terzaghi's general form, not Terzaghi's own factors (1.3 c N_c, 0.4 γ B N_γ).
  • No local or punching shear reduction is applied: for loose sand or soft clay, where local shear governs, the result is unconservative; a common practice is to repeat with c and tan φ reduced to two-thirds (Terzaghi's local shear).
  • A water table within B below the base reduces the overburden and N_γ terms (Das's three cases); the soil below it is taken as saturated at the bulk density entered.

References

  • Terzaghi (1943) general form; Prandtl–Reissner N_c
  • N_q; Vesić (1973) N_γ; De Beer (1970) shape factors (Das, Principles of Foundation Engineering)

Questions and answers

What can a 2 m square footing 1.5 m deep in 30° sand carry?

N_q 18.4, N_γ 22.4: ultimate 1 006 kPa, safe 335 kPa with a factor of 3.

What about clay with no friction?

N_c = π + 2 = 5.14: a 1.2 m strip in 50 kPa clay at 1 m depth has 275 kPa ultimate, 92 kPa safe.

Is this the allowable bearing pressure?

It is the safe value against shear failure; settlement often governs and needs its own check.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.