FireCADCalc

Pile Group Efficiency (Converse–Labarre)

Efficiency of a rectangular pile group by the Converse–Labarre formula from rows, piles per row, diameter and spacing, and the group capacity.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 3 × 3 group, 600 mm at 1.8 m2 × 4 group, 450 mm at 1.35 m

Results

Converse–Labarre applies to friction piles in clay; in sand driven piles often show efficiency ≥ 1. Spacing of 2.5–3.5 diameters is usual. Also check the group as a block.

tan⁻¹(d/s) (in degrees in the formula)18.435°
Group efficiency74.396%
Group capacity4,761.3kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 × 3 group, 600 mm at 1.8 m. The inputs, in the units selected above:

InputValue
Number of rows3.0000 -
Piles per row3.0000 -
Pile diameter600.00 mm
Centre-to-centre spacing1.8000 m
Single pile capacity1,200.0 kN

Applying the formula below gives:

ResultValue
tan⁻¹(d/s) (in degrees in the formula)18.435 °
Group efficiency72.689 %
Group capacity7,850.4 kN

Open this example in the calculator and change any input.

Formula

\(\eta = 1 - \theta\frac{(n - 1)m + (m - 1)n}{90mn}, \quad \theta = \tan^{-1}\frac ds\ (\text{degrees})\)

Variables

Symbol Meaning SI unit
\(m\) Number of rows -
\(n\) Piles per row -
\(d\) Pile diameter m
\(s\) Centre-to-centre spacing m
\(Q_u\) Single pile capacity N
\(\theta\) tan⁻¹(d/s) (in degrees in the formula; shown in degrees) rad
\(\eta\) Group efficiency -
\(Q_g\) Group capacity N

Method and standards

Converse–Labarre.

Where it is used

  • Pile caps under columns, boilers and chimneys.
  • Comparing group layouts.

Common mistakes

  • Applying it to end-bearing piles.
  • Forgetting block failure.

Assumptions and limits

  • Rectangular grid; friction piles.
  • Block failure of the group is not computed: check it separately and take the smaller capacity.

References

  • Converse–Labarre equation (Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011), ch. 11)

Questions and answers

Why is a group weaker than the sum?

Stress zones around closely spaced friction piles overlap, so each pile mobilises less shaft friction.

How can efficiency be improved?

Wider spacing; but the pile cap grows, so 2.5–3 diameters is the usual compromise.

What do the defaults represent?

A 3 × 3 group of 600 mm piles at 1.8 m spacing, each good for 1,200 kN.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.