FireCADCalc

Pile Capacity by Static Formulae (α and β Methods)

Ultimate shaft and base capacity of a pile in clay (α method) or sand (β method), with the allowable load for a chosen factor of safety.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 600 mm, 15 m bored pile in clay, c_u 60 kPa450 mm, 12 m driven pile in sand

Below about 10–20 diameters the effective vertical stress used for shaft friction and end bearing is held constant. 15 is on the cautious side; enter 100 to apply no limit.

Results

Single uniform layer, water table at the surface for γ′. Clay: Q_s = αc_uA_s, Q_b = 9c_uA_b. Sand: Q_s = βσ′_v,avgA_s, Q_b = N_qσ′_v,tipA_b, with σ′_v held constant below the critical depth. Confirm by a load test.

Shaft capacity848.23kN
Base capacity152.68kN
Ultimate capacity1,000.9kN
Allowable load400.36kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 600 mm, 15 m bored pile in clay, c_u 60 kPa. The inputs, in the units selected above:

InputValue
SoilClay (α method)
Pile diameter600.00 mm
Embedded length15.000 m
Undrained shear strength (clay)60.000 kPa
Adhesion factor (clay)0.50000 -
Effective unit weight (sand)9.0000 kN/m³
Shaft friction factor (sand)0.30000 -
Base bearing factor (sand)40.000 -
Factor of safety2.5000 -
Critical depth in diameters (sand)15.000 -

Applying the formula below gives:

ResultValue
Shaft capacity848.23 kN
Base capacity152.68 kN
Ultimate capacity1,000.9 kN
Allowable load400.36 kN

Open this example in the calculator and change any input.

Formula

\(Q_s = \alpha c_uA_s,\ Q_b = 9c_uA_b\ \text{(clay)}; \quad Q_s = \beta\bar\sigma'_vA_s,\ Q_b = N_q\sigma'_{v,tip}A_b\ \text{(sand)}\)

\(\sigma'_v(z) = \gamma' \min(z, z_c), \quad z_c = (z_c/D)\,D\)

Variables

Symbol Meaning SI unit
\(\text{soil}\) Soil -
\(D\) Pile diameter m
\(L\) Embedded length m
\(c_u\) Undrained shear strength (clay) Pa
\(\alpha\) Adhesion factor (clay) -
\(\gamma'\) Effective unit weight (sand) N/m³
\(\beta\) Shaft friction factor (sand) -
\(N_q\) Base bearing factor (sand) -
\(FS\) Factor of safety -
\(z_c/D\) Critical depth in diameters (sand) -
\(Q_s\) Shaft capacity N
\(Q_b\) Base capacity N
\(Q_u\) Ultimate capacity N
\(Q_a\) Allowable load N

Method and standards

Static capacity.

Where it is used

  • Pile foundations for boilers, chimneys and tanks.
  • Preliminary pile length.

Common mistakes

  • Ignoring negative skin friction in fill.
  • Using the β method without limiting stresses for long piles.

Assumptions and limits

  • Single layer; vertical load; water table at the ground surface (γ′ is the submerged unit weight).
  • The pile's own weight is not subtracted from Q_a; subtract it (less the displaced soil) for a net allowable load.
  • Sand: the effective vertical stress for shaft friction and end bearing stops rising below the critical depth (10–20 diameters is the usual range; 15 is the default).

References

  • α and β methods for pile capacity (Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011), ch. 11)

Questions and answers

Why is shaft friction usually larger?

A long pile has much more shaft area than base area, and base resistance needs large settlement to mobilise.

What α should I use?

About 1 for soft clay, falling to 0.3–0.5 for stiff clay; check local correlations.

What do the defaults represent?

A 600 mm, 15 m bored pile in clay with c_u = 60 kPa.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.