Worked example
Example: Cooling a batch at 80 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Overall coefficient | 350.00 W/(m²·K) |
| Jacket or coil area | 12.000 m² |
| Batch temperature | 80.000 °C |
| Jacket fluid in | 30.000 °C |
| Jacket fluid out | 40.000 °C |
| Jacket fluid specific heat | 4.1800 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Log mean temperature difference | 44.814 K |
| Heat transfer (positive: batch cooled) | 188.22 kW |
| Jacket fluid flow | 16.210 t/h |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{lm} = \frac{(T_r - t_1) - (T_r - t_2)}{\ln\frac{T_r - t_1}{T_r - t_2}}, \quad \dot Q = U A \Delta T_{lm}, \quad \dot m = \frac{\dot Q}{c(t_2 - t_1)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(U\) | Overall coefficient | W/(m²·K) |
| \(A\) | Jacket or coil area | m² |
| \(T_r\) | Batch temperature | K |
| \(t_1\) | Jacket fluid in | K |
| \(t_2\) | Jacket fluid out | K |
| \(c\) | Jacket fluid specific heat | J/(kg·K) |
| \(\Delta T_{lm}\) | Log mean temperature difference | K |
| \(\dot Q\) | Heat transfer (positive: batch cooled) | W |
| \(\dot m\) | Jacket fluid flow | kg/s |
Method and standards
LMTD.
Where it is used
- Reactor and crystalliser jackets.
- Cooling water planning.
Common mistakes
- Arithmetic mean ΔT.
- Ignoring fouling in U.
Assumptions and limits
- Well-mixed batch at constant temperature.
- The jacket fluid must warm when it cools the batch and cool when it heats it; other combinations are rejected.
References
- Q = U A ΔT_lm with the batch at uniform temperature; jacket flow from its temperature change
Questions and answers
U 350, 12 m², batch 80 °C, water 30 → 40 °C?
ΔT_lm 44.8 K: 188 kW and 16.2 t/h of water.
Heating?
Enter jacket temperatures above the batch: the duty shows negative (heat into the batch).
Where does U come from?
Film coefficients, wall and fouling, or a plant test.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.