FireCADCalc

Peng–Robinson Equation of State: Z and Density

Compressibility factor and density of a pure component by the Peng–Robinson equation of state from critical constants and acentric factor, vapour and liquid roots.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Methane 300 K, 50 barPropane 300 K, 9 bar (two phases possible)n-Butane liquid 300 K, 10 bar

Results

One real root: a single phase (or supercritical); both outputs show it.

Largest root (vapour-like)0.90177
Smallest root (liquid-like)0.90177
Density at the largest root35.662kg/m³
Density at the smallest root35.662kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Methane 300 K, 50 bar. The inputs, in the units selected above:

InputValue
Temperature26.850 °C
Pressure (absolute)50.000 bar
Critical temperature-82.590 °C
Critical pressure45.990 bar
Acentric factor0.011000 -
Molar mass16.043 kg/kmol

Applying the formula below gives:

ResultValue
Largest root (vapour-like)0.90177
Smallest root (liquid-like)0.90177
Density at the largest root35.662 kg/m³
Density at the smallest root35.662 kg/m³

Open this example in the calculator and change any input.

Formula

\(p = \frac{RT}{v - b} - \frac{a\alpha}{v^2 + 2bv - b^2}, \quad Z^3 + (B - 1)Z^2 + (A - 3B^2 - 2B)Z + (B^3 + B^2 - AB) = 0\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(p\) Pressure (absolute) Pa
\(T_c\) Critical temperature K
\(p_c\) Critical pressure Pa
\(\omega\) Acentric factor -
\(M\) Molar mass kg/kmol
\(Z_v\) Largest root (vapour-like) -
\(Z_l\) Smallest root (liquid-like) -
\(\rho_v\) Density at the largest root kg/m³
\(\rho_l\) Density at the smallest root kg/m³

Method and standards

Peng–Robinson cubic.

Where it is used

  • Gas and LPG densities.
  • Compressor and pipeline calculations.

Common mistakes

  • Gauge pressure.
  • Choosing the wrong root.

Assumptions and limits

  • Pure component.
  • With three roots the page compares the Peng–Robinson fugacity coefficients of the largest and smallest roots, ln φ = Z − 1 − ln(Z − B) − A/(2√2 B) ln[(Z + (1 + √2)B)/(Z + (1 − √2)B)], and names the stable phase.

References

  • Peng and Robinson (1976)
  • A new two-constant equation of state
  • Ind. Eng. Chem. Fundam. 15(1); a = 0.45724 R²T_c²/p_c α
  • b = 0.07780 RT_c/p_c
  • κ = 0.37464 + 1.54226ω − 0.26992ω²

Questions and answers

Methane at 300 K and 50 bar?

Z about 0.90: about 36 kg/m³.

Which root to use?

Largest for vapour, smallest for liquid; with three roots the phase of lower fugacity is stable.

Liquid density accuracy?

Peng–Robinson often errs by 5–10 % for liquids; a volume translation improves it.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.