FireCADCalc

Gas Mixture Pseudo-Critical Properties (Kay's Rule)

Pseudo-critical temperature, pressure and acentric factor of a gas mixture of up to four components by Kay's rule, with reduced conditions.

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Natural gas 85/10/5 CH4/C2H6/N2, 300 K, 50 barBiogas 60/40 CH4/CO2, 310 K, 10 bar

Results

Kay's rule is adequate here: the components' critical temperatures and pressures differ by less than a factor of two.

Pseudo-critical temperature-37.162°C
Pseudo-critical pressure57.102bar
Mixture acentric factor0.096400
Pseudo-reduced temperature1.3136
Pseudo-reduced pressure0.17513

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Natural gas 85/10/5 CH4/C2H6/N2, 300 K, 50 bar. The inputs, in the units selected above:

InputValue
Temperature26.850 °C
Pressure (absolute)50.000 bar
Mole fraction 185.000 %
T_c of 1-82.590 °C
p_c of 145.990 bar
ω of 10.011400 -
Mole fraction 210.000 %
T_c of 232.170 °C
p_c of 248.720 bar
ω of 20.099500 -
Mole fraction 35.0000 %
T_c of 3-146.95 °C
p_c of 333.980 bar
ω of 30.037700 -
Mole fraction 4 (0 = none)0 %
T_c of 430.980 °C
p_c of 473.770 bar
ω of 40.22390 -

Applying the formula below gives:

ResultValue
Pseudo-critical temperature-74.332 °C
Pseudo-critical pressure45.663 bar
Mixture acentric factor0.021525
Pseudo-reduced temperature1.5089
Pseudo-reduced pressure1.0950

Open this example in the calculator and change any input.

Formula

\(T_{pc} = \sum y_iT_{ci}, \quad p_{pc} = \sum y_ip_{ci}, \quad \omega_m = \sum y_i\omega_i\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(p\) Pressure Pa
\(y_1\) Mole fraction 1 -
\(T_{c1}\) T_c of 1 K
\(p_{c1}\) p_c of 1 Pa
\(\omega_1\) ω of 1 -
\(y_2\) Mole fraction 2 -
\(T_{c2}\) T_c of 2 K
\(p_{c2}\) p_c of 2 Pa
\(\omega_2\) ω of 2 -
\(y_3\) Mole fraction 3 -
\(T_{c3}\) T_c of 3 K
\(p_{c3}\) p_c of 3 Pa
\(\omega_3\) ω of 3 -
\(y_4\) Mole fraction 4 (0 = none) -
\(T_{c4}\) T_c of 4 K
\(p_{c4}\) p_c of 4 Pa
\(\omega_4\) ω of 4 -
\(T_{pc}\) Pseudo-critical temperature K
\(p_{pc}\) Pseudo-critical pressure Pa
\(\omega_m\) Mixture acentric factor -
\(T_r\) Pseudo-reduced temperature -
\(p_r\) Pseudo-reduced pressure -

Method and standards

Kay's rule.

Where it is used

  • Natural gas and fuel gas Z factors.
  • Corresponding-states estimates.

Common mistakes

  • Using mass fractions.
  • Applying to liquid mixtures.

Assumptions and limits

  • Mole-fraction averages, normalised when the fractions add up to between 99 and 101 % (a note shows the sum).
  • A note checks whether the components' critical temperatures and pressures differ by more than a factor of two. Pressure is absolute.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2 (pseudocritical properties of mixtures, Kay's rule)

Questions and answers

What is Kay's rule?

Mole-fraction averages of the critical temperature and pressure, used as if the mixture were a pure fluid.

When does it fail?

For components with very different critical properties, and near the true mixture critical point.

What do the defaults represent?

A natural gas of methane, ethane and nitrogen.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.