FireCADCalc

Raw Mix Proportioning: Two Components to a Target LSF

Parts of limestone per part of clay (or two raw materials) for a target Kind's lime factor or lime saturation factor, with mix moduli and clinker factor.

Inputs

Examples: Duda Example 2.3: limestone and clay, Kind KS 0.92Limestone and shale to LSF 0.95Marl and limestone to LSF 0.92

Results

Dry-basis analyses. With two materials only the lime level can be set; silica and alumina ratios follow from the materials (use three components to fix the silica ratio too). Coal ash absorbed in the kiln shifts the clinker toward lower lime.

Parts of material 1 per part of material 24.3933
Material 1 in the raw mix81.459%
Material 2 in the raw mix18.541%
Silica ratio of the mix2.5979
Alumina ratio of the mix2.3450
Loss on ignition of the mix35.289%
Raw mix per unit clinker (loss on ignition only)1.5453

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Duda Example 2.3: limestone and clay, Kind KS 0.92. The inputs, in the units selected above:

InputValue
Target factorKind's lime saturation factor
Target value0.92000 -
SiO₂ in material 1 (lime component)1.4200 %
Al₂O₃ in material 1 (lime component)0.48000 %
Fe₂O₃ in material 1 (lime component)0.38000 %
CaO in material 1 (lime component)52.600 %
Loss on ignition of material 141.000 %
SiO₂ in material 2 (clay component)62.950 %
Al₂O₃ in material 2 (clay component)18.980 %
Fe₂O₃ in material 2 (clay component)7.3700 %
CaO in material 2 (clay component)1.4000 %
Loss on ignition of material 27.0000 %

Applying the formula below gives:

ResultValue
Parts of material 1 per part of material 24.0539
Material 1 in the raw mix80.213 %
Material 2 in the raw mix19.787 %
Silica ratio of the mix2.3028
Alumina ratio of the mix2.3485
Loss on ignition of the mix34.273 %
Raw mix per unit clinker (loss on ignition only)1.5214

Open this example in the calculator and change any input.

Formula

\(x = \frac{(2.8\,KS\,S_2 + 1.65A_2 + 0.35F_2) - C_2}{C_1 - (2.8\,KS\,S_1 + 1.65A_1 + 0.35F_1)}\)

Variables

Symbol Meaning SI unit
\(\text{target}\) Target factor -
\(KS\) Target value -
\(S_{1}\) SiO₂ in material 1 (lime component) -
\(A_{1}\) Al₂O₃ in material 1 (lime component) -
\(F_{1}\) Fe₂O₃ in material 1 (lime component) -
\(C_{1}\) CaO in material 1 (lime component) -
\(LOI_1\) Loss on ignition of material 1 -
\(S_{2}\) SiO₂ in material 2 (clay component) -
\(A_{2}\) Al₂O₃ in material 2 (clay component) -
\(F_{2}\) Fe₂O₃ in material 2 (clay component) -
\(C_{2}\) CaO in material 2 (clay component) -
\(LOI_2\) Loss on ignition of material 2 -
\(x\) Parts of material 1 per part of material 2 -
\(w_1\) Material 1 in the raw mix -
\(w_2\) Material 2 in the raw mix -
\(SR\) Silica ratio of the mix -
\(AR\) Alumina ratio of the mix -
\(LOI\) Loss on ignition of the mix -
\(f_k\) Raw mix per unit clinker (loss on ignition only) -

Method and standards

Lime balance between two materials.

Where it is used

  • Raw mix design for a new quarry.
  • Adjusting kiln feed for a change in limestone quality.

Common mistakes

  • Using wet analyses.
  • Mixing material 1 and 2 roles.

Assumptions and limits

  • Dry, ignited basis consistent for both.

References

  • Duda
  • Cement Data Book
  • Vol. 1
  • 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
  • sec. 2.3 and Example 2.3

Questions and answers

Why does the result use parts per part?

Duda solves for x parts of the lime component per part of clay; the percentages follow as x/(1 + x).

Can I fix the silica ratio too?

Not with two materials; add a corrective (sand, iron ore or pyrite ash) and use the three-component calculator.

What do the defaults represent?

Duda's Example 2.3: limestone (52.60 % CaO) and clay (62.95 % SiO₂) to Kind's factor 0.92 — 4.053 parts limestone, 80.20 / 19.80 %.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.