Worked example
Example: 50 t/h, 0.25 m3/kg, 0.8 m, 3,000 rpm, full admission. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 50.000 t/h |
| Specific volume at the blade row | 0.25000 m³/kg |
| Mean blade diameter | 0.80000 m |
| Speed | 3,000.0 rpm |
| Steam velocity leaving the nozzles | 300.00 m/s |
| Nozzle exit angle | 18.000 ° |
| Arc of admission (1 = full) | 100.00 % |
| Blade blockage factor (thickness), about 0.9 | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean blade speed | 125.66 m/s |
| Axial velocity | 92.705 m/s |
| Flow area needed | 0.037454 m² |
| Blade height | 16.559 mm |
| Height-to-diameter ratio | 0.020698 |
| Velocity ratio | 0.41888 |
Open this example in the calculator and change any input.
Formula
\(A = \frac{\dot m v}{V_1\sin\alpha}, \quad h_b = \frac{A}{\pi D_m\varepsilon k}, \quad V_b = \frac{\pi D_mN}{60}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Steam flow | kg/s |
| \(v\) | Specific volume at the blade row | m³/kg |
| \(D_m\) | Mean blade diameter | m |
| \(N\) | Speed | rad/s |
| \(V_1\) | Steam velocity leaving the nozzles | m/s |
| \(\alpha\) | Nozzle exit angle | rad |
| \(\varepsilon\) | Arc of admission (1 = full) | - |
| \(k\) | Blade blockage factor (thickness), about 0.9 | - |
| \(V_b\) | Mean blade speed | m/s |
| \(V_a\) | Axial velocity | m/s |
| \(A\) | Flow area needed | m² |
| \(h_b\) | Blade height | m |
| \(h_b/D_m\) | Height-to-diameter ratio | - |
| \(V_b/V_1\) | Velocity ratio | - |
Method and standards
Continuity through the blade annulus.
Where it is used
- Preliminary stage layout.
- Checking blade heights for a new flow.
Common mistakes
- Using the absolute velocity instead of its axial component.
- Forgetting the arc of admission.
Assumptions and limits
- Uniform flow at mean diameter.
Questions and answers
Why partial admission?
In HP stages the specific volume is small; with full admission the blades would be only a few millimetres tall, so nozzles are fitted round part of the circumference to keep a reasonable blade height.
Why does the blade height grow through the turbine?
Specific volume rises a hundredfold or more from inlet to condenser, so the annulus must grow; LP blades are the longest.
What do the defaults represent?
50 t/h with 0.25 m³/kg at 0.8 m mean diameter and 3,000 rpm, 300 m/s at 18° and full admission: 126 m/s blade speed, 92.7 m/s axial velocity, 0.0375 m² and 16.6 mm blades with 0.9 blockage.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), sec. 7.3, eq. 7.41 (annulus area π D_m h_b) with continuity