FireCADCalc

EV Wall-to-Wheel Energy and Efficiency Chain

Energy drawn from the grid per kilometre from wheel energy through gearbox, motor and inverter, battery and charger efficiencies, with each stage's losses.

Inputs

Examples: Illustrative 120 Wh/km at the wheelsEfficient SiC drivetrainDelivery van

Accepted: 50 to 1,000 Wh/km
Accepted: 80 to 100 %
Accepted: 60 to 100 %
Accepted: 70 to 100 %
Accepted: 70 to 100 %
Accepted: 100 to 200,000 km

Results

Each stage divides the energy: wheel ← gearbox ← motor/inverter ← battery (round trip) ← charger. Regenerated energy can be included by lowering the wheel energy to the net traction energy. Typical wall-to-wheel efficiency is 70–80 %; DC fast charging has lower charger losses in the car but more in the station.

Battery terminal energy per km119.41Wh/km
Grid energy per km135.16Wh/km
Wall-to-wheel efficiency81.388%
Charger loss per km9.4609Wh/km
Annual grid energy2,703.1kWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 120 Wh/km at the wheels. The inputs, in the units selected above:

InputValue
Energy at the wheels per km120.00 Wh/km
Gearbox efficiency97.000 %
Motor and inverter efficiency90.000 %
Battery charge–discharge efficiency93.000 %
Charger efficiency90.000 %
Annual distance15,000 km

Applying the formula below gives:

ResultValue
Battery terminal energy per km137.46 Wh/km
Grid energy per km164.23 Wh/km
Wall-to-wheel efficiency73.070 %
Charger loss per km16.423 Wh/km
Annual grid energy2,463.4 kWh

Open this example in the calculator and change any input.

Formula

\(e_{wall} = \frac{e_w}{\eta_g\eta_m\eta_b\eta_c}, \quad \eta_{tot} = \eta_g\eta_m\eta_b\eta_c\)

Variables

Symbol Meaning SI unit
\(e_w\) Energy at the wheels per km J/m
\(\eta_g\) Gearbox efficiency -
\(\eta_m\) Motor and inverter efficiency -
\(\eta_b\) Battery charge–discharge efficiency -
\(\eta_c\) Charger efficiency -
\(d\) Annual distance m
\(e_b\) Battery terminal energy per km J/m
\(e_{wall}\) Grid energy per km J/m
\(\eta_{tot}\) Wall-to-wheel efficiency -
\(\Delta e_c\) Charger loss per km J/m
\(E_{year}\) Annual grid energy J

Method and standards

Efficiency chain.

Where it is used

  • Electricity budgets for EV fleets.
  • Comparing well-to-wheel emissions.

Common mistakes

  • Using dashboard consumption as grid consumption.
  • Counting regenerated energy twice.

Assumptions and limits

  • Constant stage efficiencies.

References

  • Series efficiency chain

Questions and answers

Why is the grid figure higher than the dashboard figure?

Dashboards usually show battery energy out; charger and battery charging losses add another 10–20 % at the meter.

Where are the largest losses?

Usually the charger and the motor and inverter at light load; the gearbox loses only a few percent.

What do the defaults represent?

An illustrative car needing 120 Wh/km at the wheels with 97 % gearbox, 90 % motor-inverter, 93 % battery and 90 % charger efficiencies, driven 15,000 km a year.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Lowry, Electric Vehicle Technology Explained, 2nd ed. (Wiley, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.