FireCADCalc

EV Range Loss from Cabin Heating

Extra energy per kilometre and the range with cabin heating by resistive heater or heat pump, from heater power, average speed and driving consumption.

Inputs

Examples: Illustrative 60 kWh car, 3 kW resistive at 35 km/hHeat pump COP 2.5Motorway 100 km/h, resistive

Accepted: 1 to 200 kWh
Accepted: 100 to 500 Wh/km
Accepted: 0 to 10 kW
Accepted: 1 to 5
Accepted: 3.6 to 144 km/h

Results

Heating energy per km = P_h/(COP·v̄): heating draws power per hour, so slow city driving loses the most range. A heat pump with COP 2–3 cuts the loss sharply above about −10 °C. Cold also raises battery resistance and driving consumption, which this calculator leaves in e_d.

Heating energy per km34.286Wh/km
Range without heating375.00km
Range with heating308.82km
Range loss17.647%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 60 kWh car, 3 kW resistive at 35 km/h. The inputs, in the units selected above:

InputValue
Usable battery energy60.000 kWh
Driving consumption without heating160.00 Wh/km
Cabin heat demand3.0000 kW
Heater COP (1 for resistive)1.0000 -
Average speed35.000 km/h

Applying the formula below gives:

ResultValue
Heating energy per km85.714 Wh/km
Range without heating375.00 km
Range with heating244.19 km
Range loss34.884 %

Open this example in the calculator and change any input.

Formula

\(e_h = \frac{P_h}{COP\cdot\bar v}, \quad R_h = \frac{E_u}{e_d + e_h}\)

Variables

Symbol Meaning SI unit
\(E_u\) Usable battery energy J
\(e_d\) Driving consumption without heating J/m
\(P_h\) Cabin heat demand W
\(COP\) Heater COP (1 for resistive) -
\(\bar v\) Average speed m/s
\(e_h\) Heating energy per km J/m
\(R_0\) Range without heating m
\(R_h\) Range with heating m
\(\Delta R/R_0\) Range loss -

Method and standards

Heating energy.

Where it is used

  • Winter range planning for EV fleets.
  • Comparing heater technologies.

Common mistakes

  • Using peak heater power for steady heating.
  • Ignoring speed's effect on heating per kilometre.

Assumptions and limits

  • Constant heat demand and speed.

References

  • Energy per distance balance

Questions and answers

Why is winter range worse in town?

Heater power is per hour, and at low average speed each kilometre takes longer, so more heating energy goes into it.

How much does a heat pump help?

With COP 2–3 the heating energy falls to a half or a third of a resistive heater's.

What do the defaults represent?

An illustrative 60 kWh car using 160 Wh/km, with a 3 kW resistive heater at 35 km/h average.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Lowry, Electric Vehicle Technology Explained, 2nd ed. (Wiley, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.