FireCADCalc

EV Battery Pack Heat and Coolant Flow

Heat generated by a battery pack from its current and internal resistance, plus other loads, and the coolant mass and volume flow for a chosen temperature rise.

Inputs

Examples: Illustrative 250 A fast chargeHighway at 120 AWater coolant, high current

Accepted: 0 to 100,000 A
Accepted: 1E-5 to 10 Ω
Accepted: 0 to 10,000 kW
Accepted: 0.5 to 5 kJ/(kg·K)
Accepted: 500 to 2,000 kg/m³
Accepted: 0.1 to 50 K

Results

Joule heat in the cells is I²R with the pack's DC internal resistance (rising at low temperature and with ageing); entropic (reversible) heat is neglected, which is reasonable at high rates. The coolant flow follows from Q = ṁc_pΔT. A 50 % ethylene glycol–water mix has c_p ≈ 3.5 kJ/kg·K and ρ ≈ 1,060 kg/m³. Keep ΔT across the pack small (3–5 K) so cells age evenly.

Battery Joule heat5.0000kW
Total heat to remove6.5000kW
Coolant mass flow0.46429kg/s
Coolant volume flow26.280L/min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 A fast charge. The inputs, in the units selected above:

InputValue
Pack current (RMS over the duty)250.00 A
Pack internal resistance0.080000 Ω
Other heat into the loop (charger, electronics)1.5000 kW
Coolant specific heat3.5000 kJ/(kg·K)
Coolant density1,060.0 kg/m³
Coolant temperature rise4.0000 K

Applying the formula below gives:

ResultValue
Battery Joule heat5.0000 kW
Total heat to remove6.5000 kW
Coolant mass flow0.46429 kg/s
Coolant volume flow26.280 L/min

Open this example in the calculator and change any input.

Formula

\(\dot Q = I^2R_{pack} + \dot Q_x, \quad \dot m = \frac{\dot Q}{c_p\Delta T}, \quad \dot V = \frac{\dot m}{\rho}\)

Variables

Symbol Meaning SI unit
\(I\) Pack current (RMS over the duty) A
\(R_{pack}\) Pack internal resistance Ω
\(\dot Q_x\) Other heat into the loop (charger, electronics) W
\(c_p\) Coolant specific heat J/(kg·K)
\(\rho\) Coolant density kg/m³
\(\Delta T\) Coolant temperature rise K
\(\dot Q_b\) Battery Joule heat W
\(\dot Q\) Total heat to remove W
\(\dot m\) Coolant mass flow kg/s
\(\dot V\) Coolant volume flow m³/s

Method and standards

Coolant flow.

Where it is used

  • Sizing pack cooling pumps and chillers.
  • Checking fast-charge thermal limits.

Common mistakes

  • Using the cell resistance instead of the pack resistance.
  • Using water's c_p for glycol.

Assumptions and limits

  • Steady state; reversible heat neglected; uniform resistance.

References

  • Joule heating and coolant heat balance

Questions and answers

Which current should I use?

The RMS current over a representative duty, such as a fast charge or a hill climb; heat goes with the square of current.

Why keep the coolant rise small?

Cell temperature differences cause uneven ageing; packs aim for a few kelvin across the pack.

What do the defaults represent?

An illustrative 250 A fast charge through a 0.08 Ω pack with 1.5 kW from the charger, glycol coolant rising 4 K.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bosch Automotive Handbook, 11th ed. (Robert Bosch GmbH / Wiley, 2022)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.