Worked example
Example: de Smet bagasse rate. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Diffuser width | 6.5000 m |
| Length of bed under percolation | 45.000 m |
| Percolation rate | 17.000 m/h |
| Bed depth | 1.8000 m |
| Juice density | 1,050.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Juice circulated | 4,972.5 m³/h |
| Circulation per tonne cane | 20.884 kg/kg |
| Time for juice to cross the bed | 6.3529 min |
Open this example in the calculator and change any input.
Formula
\(\dot V = u\,L\,Z, \quad \frac{\dot m_J}{A} = \frac{\rho_J \dot V}{A}, \quad t_p = \frac{H}{u}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(L\) | Diffuser width | m |
| \(Z\) | Length of bed under percolation | m |
| \(u\) | Percolation rate | m/s |
| \(H\) | Bed depth | m |
| \(\rho_J\) | Juice density | kg/m³ |
| \(\dot V\) | Juice circulated | m³/s |
| \(\dot m_J/A\) | Circulation per tonne cane | kg/kg |
| \(t_p\) | Time for juice to cross the bed | s |
Method and standards
Continuity over the bed area.
Where it is used
- Sizing recirculation pumps.
- Checking flooding risk.
Common mistakes
- Using the whole diffuser length where only part percolates.
- Mixing m/h and m/min.
Assumptions and limits
- Uniform percolation over the area.
- The crossing time uses the superficial percolation rate; the juice moves faster in the voids of the bed, so the time is an upper estimate.
- Hugot's heating-water multiples in the note are for comparison only; they are not checked against the computed circulation.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 23
- percolation and recirculation
- pp. 373–391
Questions and answers
What limits percolation?
Fine preparation and high compaction slow it; mud and soil in the cane block the bed.
Why circulate so much juice?
Each stage sprays far more juice than passes forward, so the bed is washed many times.
Juice time through the bed?
Hugot: about 2.5–3.5 min at 0.7 m/min.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.