FireCADCalc

Diffuser Megasse Dewatering Balance

Wet bagasse leaving a diffuser and after the dewatering roller and mills, the water pressed out and the dewatering power, from moistures and fibre (Hugot ch. 23).

Sugar mill and cogenerationBoiler

Inputs

Examples: BMA typeSilver cone press

Hugot: 83–86 %.
Hugot: cone press 3, French press 4.5 kW per t cane/h; BMA dewatering mills more.

Results

Press water carries sugar and fine bagasse; it goes back to the diffuser, usually after heating and screening.

Megasse leaving the diffuser165.54t/h
Bagasse after the dewatering roller77.250t/h
Final bagasse44.567t/h
Press water returned120.97t/h
Dewatering power450.00kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: BMA type. The inputs, in the units selected above:

InputValue
Crushing rate250.00 t/h
Fibre % cane14.500 %
Dissolved solids in bagasse per unit fibre4.0000 %
Moisture of megasse leaving the diffuser85.000 %
Moisture after the dewatering roller or press76.000 %
Final bagasse moisture (wet basis)50.000 %
Dewatering power per tonne cane per hour4.5000 kWh/t

Applying the formula below gives:

ResultValue
Megasse leaving the diffuser251.33 t/h
Bagasse after the dewatering roller157.08 t/h
Final bagasse75.400 t/h
Press water returned175.93 t/h
Dewatering power1,125.0 kW

Open this example in the calculator and change any input.

Formula

\(M_i = \frac{A f(1 + r)}{1 - w_i}, \quad W_p = M_0 - M_2, \quad P = e A\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(f\) Fibre % cane -
\(r\) Dissolved solids in bagasse per unit fibre -
\(w_0\) Moisture of megasse leaving the diffuser -
\(w_1\) Moisture after the dewatering roller or press -
\(w_2\) Final bagasse moisture (wet basis) -
\(e\) Dewatering power per tonne cane per hour J/kg
\(M_0\) Megasse leaving the diffuser kg/s
\(M_1\) Bagasse after the dewatering roller kg/s
\(M_2\) Final bagasse kg/s
\(W_p\) Press water returned kg/s
\(P\) Dewatering power W

Method and standards

Dry-solids balance.

Where it is used

  • Sizing dewatering mills and press-water pumps.
  • Boiler fuel moisture estimates.

Common mistakes

  • Leaving out dissolved solids.
  • Using moisture on dry basis.

Assumptions and limits

  • Constant solids through the presses: one dissolved-solids ratio r for all stages. The press water removes some sugar, so the final bagasse flow is slightly overstated.
  • Moistures are on the wet basis (water per kg of wet bagasse); convert a dry-basis figure before using it in other calculators.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 23
  • megasse and dewatering (BMA and Silver data)
  • pp. 383–392

Questions and answers

Why is megasse so wet?

It leaves the diffuser saturated with about 85 % water; pressing brings it to about 50 % for the boilers.

Where does the press water go?

Back to the diffuser, so its sugar is not lost.

Feed openings of dewatering mills?

Hugot: feed to delivery ratios of 3:1 to 4:1, wider than normal mills.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.