Cane Diffuser Width and Residence Time (Hugot)

Width of a moving-bed cane or bagasse diffuser from fibre rate, bed depth, apron speed and compaction (Hugot p. 394), its residence time and the 25 mm per t/h rule.

Sugar mill and cogeneration

Inputs

Examples: 250 TCH cane diffuserBagasse diffuser

Hugot: de Smet 0.24–0.90 m/min, generally 0.65; BMA about 1 m/min.
Hugot: de Smet normally 1.8 m (2 m maximum); BMA 1.35 m.
Hugot: 60–80 kg fibre/m³; above 80 the bed floods.

Results

Hugot: de Smet residence 30–45 min for bagasse and 55–65 min for cane diffusers; juice passes in 20–35 min.

Diffuser width5.5115m
Bagasse residence time40.000min
Width by the 25 mm per t cane/h rule3.7500m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 250 TCH cane diffuser. The inputs, in the units selected above:

InputValue
Crushing rate250.00 t/h
Fibre % cane14.500 %
Apron (bed) speed0.65000 m/min
Bed depth1.8000 m
Compaction (fibre per m³ of bed)80.000 kg/m³
Share of the cross-section filled (scrapers, slope)80.000 %
Length of the extraction zone48.000 m

Applying the formula below gives:

ResultValue
Diffuser width8.0685 m
Bagasse residence time73.846 min
Width by the 25 mm per t cane/h rule6.2500 m

Open this example in the calculator and change any input.

Formula

\(L = \frac{A f}{v\,H\,t\,\varphi}, \quad t_r = \frac{Z}{v}, \quad L_r = 0.025\,A\ [\mathrm{m};\ A\ \mathrm{t/h}]\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(f\) Fibre % cane -
\(v\) Apron (bed) speed m/s
\(H\) Bed depth m
\(t\) Compaction (fibre per m³ of bed) kg/m³
\(\varphi\) Share of the cross-section filled (scrapers, slope) -
\(Z\) Length of the extraction zone m
\(L\) Diffuser width m
\(t_r\) Bagasse residence time s
\(L_r\) Width by the 25 mm per t cane/h rule m

Method and standards

Continuity of fibre through the bed (Hugot after Van Hengel).

Where it is used

  • Sizing diffusers.
  • Checking residence after a crush increase.

Common mistakes

  • Using cane rate instead of fibre rate.
  • Ignoring the scraper space in the cross-section.

Assumptions and limits

  • Uniform bed; constant compaction.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 23
  • diffuser capacity (Van Hengel, p. 394) and de Smet and BMA data
  • pp. 369–392

Questions and answers

Why does compaction limit capacity?

Juice must percolate down through the bed; above about 80 kg fibre/m³ it cannot pass fast enough and the bed floods.

Cane or bagasse diffuser?

A bagasse diffuser follows a first mill and needs a shorter residence; a cane diffuser takes all the prepared cane.

What is the 25 mm rule?

De Smet and BMA build about 25 mm of width per tonne of cane per hour.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.