Worked example
Example: 250 TCH cane diffuser. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Fibre % cane | 14.500 % |
| Apron (bed) speed | 0.65000 m/min |
| Bed depth | 1.8000 m |
| Compaction (fibre per m³ of bed) | 80.000 kg/m³ |
| Share of the cross-section filled (scrapers, slope) | 80.000 % |
| Length of the extraction zone | 48.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Diffuser width | 8.0685 m |
| Bagasse residence time | 73.846 min |
| Width by the 25 mm per t cane/h rule | 6.2500 m |
Open this example in the calculator and change any input.
Formula
\(L = \frac{A f}{v\,H\,t\,\varphi}, \quad t_r = \frac{Z}{v}, \quad L_r = 0.025\,A\ [\mathrm{m};\ A\ \mathrm{t/h}]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(f\) | Fibre % cane | - |
| \(v\) | Apron (bed) speed | m/s |
| \(H\) | Bed depth | m |
| \(t\) | Compaction (fibre per m³ of bed) | kg/m³ |
| \(\varphi\) | Share of the cross-section filled (scrapers, slope) | - |
| \(Z\) | Length of the extraction zone | m |
| \(L\) | Diffuser width | m |
| \(t_r\) | Bagasse residence time | s |
| \(L_r\) | Width by the 25 mm per t cane/h rule | m |
Method and standards
Continuity of fibre through the bed (Hugot after Van Hengel).
Where it is used
- Sizing diffusers.
- Checking residence after a crush increase.
Common mistakes
- Using cane rate instead of fibre rate.
- Ignoring the scraper space in the cross-section.
Assumptions and limits
- Uniform bed; constant compaction.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 23
- diffuser capacity (Van Hengel, p. 394) and de Smet and BMA data
- pp. 369–392
Questions and answers
Why does compaction limit capacity?
Juice must percolate down through the bed; above about 80 kg fibre/m³ it cannot pass fast enough and the bed floods.
Cane or bagasse diffuser?
A bagasse diffuser follows a first mill and needs a shorter residence; a cane diffuser takes all the prepared cane.
What is the 25 mm rule?
De Smet and BMA build about 25 mm of width per tonne of cane per hour.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.