FireCADCalc

Nitrogen Blanketing Flow for Tank Pump-Out and Cooling

Nitrogen flow to hold the blanket pressure in a storage tank while it is pumped out and while its vapour space cools, as normal volume flow.

Inputs

Examples: Illustrative 100 m3/h out, 500 m3 vapour spaceLarge tank rainstorm 40 K/hSmall day tank

Accepted: 0 to 36,000 m³/h
Accepted: 0.1 to 100,000 m³
Accepted: 0 to 360 °C/h
Accepted: -43.15 to 126.85 °C
Accepted: 80 to 200 kPa

Results

Ideal gas at constant pressure: replace the liquid volume pumped out and the vapour-space shrinkage V·(dT/dt)/T, converted to 0 °C, 1 atm. Condensation of product vapour during cooling adds to this; codes for tank venting give design cooling rates.

Nitrogen for pump-out90.549Nm³/h
Nitrogen for cooling14.935Nm³/h
Total nitrogen flow105.48Nm³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 m3/h out, 500 m3 vapour space. The inputs, in the units selected above:

InputValue
Liquid pump-out rate100.00 m³/h
Vapour space volume500.00 m³
Cooling rate of the vapour space10.000 °C/h
Vapour space temperature30.000 °C
Blanket pressure (absolute)101.83 kPa

Applying the formula below gives:

ResultValue
Nitrogen for pump-out90.549 Nm³/h
Nitrogen for cooling14.935 Nm³/h
Total nitrogen flow105.48 Nm³/h

Open this example in the calculator and change any input.

Formula

\(\dot V_{N_2} = \left(Q_{out} + V_v\frac{\dot T}{T}\right)\frac{p}{p_n}\frac{T_n}{T}\)

Variables

Symbol Meaning SI unit
\(Q_{out}\) Liquid pump-out rate m³/s
\(V_v\) Vapour space volume m³
\(\dot T\) Cooling rate of the vapour space K/s
\(T\) Vapour space temperature K
\(p\) Blanket pressure (absolute) Pa
\(\dot V_1\) Nitrogen for pump-out Nm³/s
\(\dot V_2\) Nitrogen for cooling Nm³/s
\(\dot V_{N_2}\) Total nitrogen flow Nm³/s

Method and standards

Blanket gas balance.

Where it is used

  • Blanketing valve and nitrogen supply sizing.
  • Estimating nitrogen consumption.

Common mistakes

  • Forgetting thermal breathing.
  • Mixing actual and normal cubic metres.

Assumptions and limits

  • Ideal gas; uniform vapour-space temperature.

References

  • Constant-pressure gas balance of a tank vapour space
  • Ideal gas law

Questions and answers

Why does cooling need nitrogen?

When rain or night cools the vapour space, the gas contracts; without make-up the tank would draw a vacuum or suck in air.

Which is usually larger?

On big tanks with large vapour spaces, sudden cooling (e.g. a rainstorm) often exceeds the pump-out demand.

What do the defaults represent?

An illustrative tank pumped out at 100 m³/h with 500 m³ of vapour space cooling at 10 K per hour, blanketed at 5 mbar gauge.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.