FireCADCalc

Liquid Sloshing Natural Frequency in a Tank

First sloshing natural frequency and period of liquid in a rectangular or upright cylindrical tank from size and liquid depth (linear potential-flow theory).

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative 10 m tank, 6 m deepLarge 40 m crude tank, 15 mRectangular road tanker compartment

Accepted: 0.1 to 200 m
Accepted: 0.01 to 100 m

Results

ω² = gk·tanh(kh), with k = π/L for a rectangular tank and k = 1.841/R for an upright cylinder (first root of J₁′). Large storage tanks slosh with periods of several seconds, close to long-period earthquake motion; seismic design uses this period for the convective (sloshing) pressure and freeboard.

First sloshing circular frequency0.89191rad/s
First sloshing frequency0.14195Hz
Sloshing period7.0447s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 m tank, 6 m deep. The inputs, in the units selected above:

InputValue
Tank shapeUpright cylinder
Length in motion direction, or diameter10.000 m
Liquid depth6.0000 m

Applying the formula below gives:

ResultValue
First sloshing circular frequency1.8775 rad/s
First sloshing frequency0.29882 Hz
Sloshing period3.3465 s

Open this example in the calculator and change any input.

Formula

\(\omega_1^2 = gk\tanh(kh), \quad k = \frac{\pi}{L}\ \text{(rectangular)}, \quad k = \frac{1.841}{R}\ \text{(cylinder)}\)

Variables

Symbol Meaning SI unit
\(\text{shape}\) Tank shape -
\(L\) Length in motion direction, or diameter m
\(h\) Liquid depth m
\(\omega_1\) First sloshing circular frequency rad/s
\(f_1\) First sloshing frequency 1/s
\(T_1\) Sloshing period s

Method and standards

Sloshing.

Where it is used

  • Seismic design of storage tanks.
  • Road and rail tankers, ship tanks.

Common mistakes

  • Using the full height instead of liquid depth.
  • Using diameter where radius is needed.

Assumptions and limits

  • Linear, inviscid, rigid tank; first mode.

References

  • Linear sloshing theory

Questions and answers

Why do big tanks slosh so slowly?

Sloshing frequency falls with tank size; a 30 m tank has a period of about 6 seconds.

Where is sloshing period used?

For the convective part of seismic loads, for freeboard to avoid roof damage, and to avoid resonance with vehicle or ship motion.

What do the defaults represent?

An illustrative upright tank of 10 m diameter with 6 m of liquid.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ibrahim, Liquid Sloshing Dynamics (Cambridge, 2005)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.