Worked example
Example: Illustrative 10 m tank, 6 m deep. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tank shape | Upright cylinder |
| Length in motion direction, or diameter | 10.000 m |
| Liquid depth | 6.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| First sloshing circular frequency | 1.8775 rad/s |
| First sloshing frequency | 0.29882 Hz |
| Sloshing period | 3.3465 s |
Open this example in the calculator and change any input.
Formula
\(\omega_1^2 = gk\tanh(kh), \quad k = \frac{\pi}{L}\ \text{(rectangular)}, \quad k = \frac{1.841}{R}\ \text{(cylinder)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{shape}\) | Tank shape | - |
| \(L\) | Length in motion direction, or diameter | m |
| \(h\) | Liquid depth | m |
| \(\omega_1\) | First sloshing circular frequency | rad/s |
| \(f_1\) | First sloshing frequency | 1/s |
| \(T_1\) | Sloshing period | s |
Method and standards
Sloshing.
Where it is used
- Seismic design of storage tanks.
- Road and rail tankers, ship tanks.
Common mistakes
- Using the full height instead of liquid depth.
- Using diameter where radius is needed.
Assumptions and limits
- Linear, inviscid, rigid tank; first mode.
References
- Linear sloshing theory
Questions and answers
Why do big tanks slosh so slowly?
Sloshing frequency falls with tank size; a 30 m tank has a period of about 6 seconds.
Where is sloshing period used?
For the convective part of seismic loads, for freeboard to avoid roof damage, and to avoid resonance with vehicle or ship motion.
What do the defaults represent?
An illustrative upright tank of 10 m diameter with 6 m of liquid.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ibrahim, Liquid Sloshing Dynamics (Cambridge, 2005)