FireCADCalc

Wave Force on a Vertical Pile (Morison Equation)

Maximum drag, inertia and total wave force on a vertical cylindrical pile from the wave height, period, water depth and pile diameter, with linear wave kinematics.

Inputs

Examples: Illustrative: 0.8 m pile, 15 m depth, 3 m 9 s waveLarge 2.5 m monopile, 25 m, 5 m 11 s (inertia dominated)Slender 0.3 m brace, 10 m, 4 m 8 s (drag dominated)

Accepted: 0.05 to 30 m
Accepted: 1 to 30 s
Accepted: 0.5 to 500 m
Accepted: 0.01 to 10 m
Accepted: 0.3 to 2
Accepted: 1 to 2.5
Accepted: 990 to 1,040 kg/m³

Results

Morison: F = ∫[C_M ρ(πD²/4)u̇ + ½ρC_D D u|u|]dz from the bed to the still-water level, with linear wave kinematics. Wave crest kinematics above still water, current and marine growth are not included.

Wavelength70.883m
Maximum drag force5.8627kN
Maximum inertia force1.8151kN
Maximum total force6.0032kN
Phase of the maximum before the crest (0 at the crest)8.9053°
Keulegan–Carpenter number u_max T/D59.029
Diameter-to-wavelength ratio (Morison valid below about 0.2)0.004232

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 0.8 m pile, 15 m depth, 3 m 9 s wave. The inputs, in the units selected above:

InputValue
Wave height3.0000 m
Wave period9.0000 s
Water depth15.000 m
Pile diameter0.80000 m
Drag coefficient (0.6–1.2)1.0000 -
Inertia coefficient (1.5–2.0)2.0000 -
Water density1,025.0 kg/m³

Applying the formula below gives:

ResultValue
Wavelength95.551 m
Maximum drag force7.0543 kN
Maximum inertia force11.456 kN
Maximum total force11.706 kN
Phase of the maximum before the crest (0 at the crest)54.293 °
Keulegan–Carpenter number u_max T/D15.587
Diameter-to-wavelength ratio (Morison valid below about 0.2)0.008372

Open this example in the calculator and change any input.

Formula

\(F = \int_{-d}^{0}\left[C_M\rho\frac{\pi D^2}{4}\dot u + \tfrac{1}{2}\rho C_DDu|u|\right]dz, \quad F_{max} = F_D + \frac{F_I^2}{4F_D}\ (F_I < 2F_D), \ \text{else}\ F_I\)

Variables

Symbol Meaning SI unit
\(H\) Wave height m
\(T\) Wave period s
\(d\) Water depth m
\(D\) Pile diameter m
\(C_D\) Drag coefficient (0.6–1.2) -
\(C_M\) Inertia coefficient (1.5–2.0) -
\(\rho\) Water density kg/m³
\(L\) Wavelength m
\(F_{D,max}\) Maximum drag force N
\(F_{I,max}\) Maximum inertia force N
\(F_{max}\) Maximum total force N
\(\theta_{max}\) Phase of the maximum before the crest (0 at the crest) rad
\(KC\) Keulegan–Carpenter number u_max T/D -
\(D/L\) Diameter-to-wavelength ratio (Morison valid below about 0.2) -

Method and standards

Morison wave force.

Where it is used

  • Jetty and pier piles, offshore jackets and risers.
  • Navigation structures and coastal outfalls.

Common mistakes

  • Using Morison for large diameters (D/L above about 0.2) where diffraction matters.
  • Forgetting marine growth, which increases D and C_D.

Assumptions and limits

  • Linear waves, slender vertical cylinder, integration to still water level.

References

  • Morison equation with linear wave kinematics

Questions and answers

When does inertia dominate over drag?

For large piles relative to the wave orbit (small KC, below about 5–10) the inertia term dominates; slender members in large waves are drag-dominated.

Why does the peak force not occur at the crest?

Inertia force peaks when the water accelerates most, a quarter period before the crest; the total peak lies between.

What do the defaults represent?

An illustrative 0.8 m jetty pile in 15 m of water under a 3 m, 9 s wave.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

US Army Corps of Engineers, Coastal Engineering Manual, EM 1110-2-1100 (2002), Part II ch. 1 and Part VI ch. 5, Dean and Dalrymple, Water Wave Mechanics for Engineers and Scientists (World Scientific, 1991), ch. 12

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.