FireCADCalc

Furnace Available Heat and Fuel Saved by Air Preheat

Available heat of natural gas firing at a flue exit temperature and excess air, with and without combustion air preheat, the fuel saved and the gross input.

IAPWS-IF97 (water and steam)Burner and furnace

Inputs

Examples: Trinks: 1800 F exit, 10 % excess air, 800 F air against 60 FReheat furnace, 1150 C exit, 450 C recuperator airForge furnace, 1300 C exit, cold air

Results

Available heat is the gross heat of combustion less the heat carried out by the flue gas (from 25 °C, water as vapour) plus the sensible heat brought in by the air. No dissociation: above about 1,600 °C exit the real available heat is a little lower. Every furnace loss costs loss ÷ available heat in fuel (Trinks).

Available heat with preheated air (gross basis)53.510%
Available heat of the base case37.798%
Fuel saved against the base case29.362%
Gross fuel input with preheat28,032kW
Gross fuel input in the base case39,684kW
Fuel gas flow with preheat2,502.2Nm³/h
Gross calorific value of the gas40.331MJ/Nm³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Trinks: 1800 F exit, 10 % excess air, 800 F air against 60 F. The inputs, in the units selected above:

InputValue
Methane in the fuel gas90.000 %
Ethane5.0000 %
Propane1.0000 %
Nitrogen4.0000 %
Excess air10.000 %
Flue gas exit temperature from the furnace982.22 °C
Combustion air temperature (preheated)426.67 °C
Air temperature of the base case15.556 °C
Heat needed by the load plus furnace losses2,000.0 kW

Applying the formula below gives:

ResultValue
Available heat with preheated air (gross basis)62.183 %
Available heat of the base case47.690 %
Fuel saved against the base case23.307 %
Gross fuel input with preheat3,216.3 kW
Gross fuel input in the base case4,193.8 kW
Fuel gas flow with preheat287.80 Nm³/h
Gross calorific value of the gas40.232 MJ/Nm³

Open this example in the calculator and change any input.

Formula

\(AH = \frac{GCV - \Delta H_{flue}(T_{ex}) - n_{H_2O}L_{25} + \Delta H_{air}(T_a)}{GCV}, \quad \text{saving} = 1 - \frac{AH_0}{AH}, \quad Q_{in} = \frac{Q}{AH}\)

Variables

Symbol Meaning SI unit
\(y_{CH_4}\) Methane in the fuel gas -
\(y_{C_2H_6}\) Ethane -
\(y_{C_3H_8}\) Propane -
\(y_{N_2}\) Nitrogen -
\(EA\) Excess air -
\(T_{ex}\) Flue gas exit temperature from the furnace K
\(T_a\) Combustion air temperature (preheated) K
\(T_0\) Air temperature of the base case K
\(Q\) Heat needed by the load plus furnace losses W
\(AH\) Available heat with preheated air (gross basis) -
\(AH_0\) Available heat of the base case -
\(1 - AH_0/AH\) Fuel saved against the base case -
\(Q/AH\) Gross fuel input with preheat W
\(Q/AH_0\) Gross fuel input in the base case W
\(\dot V_f\) Fuel gas flow with preheat Nm³/s
\(GCV\) Gross calorific value of the gas J/m³

Method and standards

Available-heat balance on the gross basis.

Where it is used

  • Reheat, forge and heat-treatment furnaces.
  • Justifying recuperators and regenerative burners.

Common mistakes

  • Using the stack temperature after the recuperator as the exit temperature.
  • Mixing gross and net bases.

Assumptions and limits

  • Complete combustion; dry air.

References

  • Trinks
  • Mawhinney
  • Shannon
  • Reed and Garvey
  • Industrial Furnaces
  • 6th ed. (Wiley, 2004)
  • ch. 5 (available heat, fuel saving by air preheat, Example 5.3)
  • NIST Shomate gas enthalpies and IAPWS-IF97 latent heat (engine)

Questions and answers

What is available heat?

The part of the fuel's gross heat left in the furnace after the flue gas leaves at its exit temperature; at 1,800 °F with cold air only about half of natural gas heat is available.

Why does preheating save so much fuel in hot furnaces?

The air brings back heat that would otherwise leave in the flue; Trinks's natural gas at 1,800 °F goes from 48 % to 62 % available heat with 800 °F air.

What do the defaults represent?

Trinks's natural gas (90 % CH₄, 5 % C₂H₆, 1 % C₃H₈, 4 % N₂) at 1,800 °F exit and 10 % excess air, with 800 °F against 60 °F air, for 2 MW of heat needed.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.