FireCADCalc

Martensite Start Temperature (Andrews Linear)

Martensite start temperature (Ms) of a low-alloy steel from its carbon, manganese, nickel, chromium and molybdenum contents by Andrews' linear formula.

Inputs

Examples: 4340-typePlain 0.2 % COutside range, 0.8 % C

Results

Martensite start temperature430.08°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 4340-type. The inputs, in the units selected above:

InputValue
Carbon (wt %)0.40000 -
Manganese (wt %)0.75000 -
Nickel (wt %)1.8000 -
Chromium (wt %)0.80000 -
Molybdenum (wt %)0.25000 -

Applying the formula below gives:

ResultValue
Martensite start temperature303.58 °C

Open this example in the calculator and change any input.

Formula

\(M_s(°C) = 539 - 423C - 30.4Mn - 17.7Ni - 12.1Cr - 7.5Mo\)

Variables

Symbol Meaning SI unit
\(C\) Carbon (wt %) -
\(Mn\) Manganese (wt %) -
\(Ni\) Nickel (wt %) -
\(Cr\) Chromium (wt %) -
\(Mo\) Molybdenum (wt %) -
\(M_s\) Martensite start temperature K

Method and standards

Andrews linear.

Where it is used

  • Heat treatment of shafts, gears and bolts.
  • Weld cracking discussions.

Common mistakes

  • Weight % as fractions.
  • High-alloy steels outside the range.

Assumptions and limits

  • Low-alloy steels, full austenitisation. Compositions far outside Andrews' data that would give a temperature below absolute zero are rejected.
  • Compositions are entered as plain weight-per-cent numbers (0.4 for 0.4 % C), unlike the Andrews critical temperatures calculator, which takes them as percentages; the inputs are kept as they are so saved links keep their meaning.

References

  • Andrews (1965)
  • J. Iron Steel Inst. 203: Ms (°C) = 539 − 423C − 30.4Mn − 17.7Ni − 12.1Cr − 7.5Mo

Questions and answers

4340-type steel (0.4 C, 0.75 Mn, 1.8 Ni, 0.8 Cr, 0.25 Mo)?

Ms about 304 °C.

Why does carbon dominate?

It stabilises austenite strongly: about 42 °C lower per 0.1 % C.

Use?

Set quench and austempering temperatures and judge cracking risk.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.