Worked example
Example: 4340-type. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Carbon (wt %) | 0.40000 - |
| Manganese (wt %) | 0.75000 - |
| Nickel (wt %) | 1.8000 - |
| Chromium (wt %) | 0.80000 - |
| Molybdenum (wt %) | 0.25000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Martensite start temperature | 303.58 °C |
Open this example in the calculator and change any input.
Formula
\(M_s(°C) = 539 - 423C - 30.4Mn - 17.7Ni - 12.1Cr - 7.5Mo\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Carbon (wt %) | - |
| \(Mn\) | Manganese (wt %) | - |
| \(Ni\) | Nickel (wt %) | - |
| \(Cr\) | Chromium (wt %) | - |
| \(Mo\) | Molybdenum (wt %) | - |
| \(M_s\) | Martensite start temperature | K |
Method and standards
Andrews linear.
Where it is used
- Heat treatment of shafts, gears and bolts.
- Weld cracking discussions.
Common mistakes
- Weight % as fractions.
- High-alloy steels outside the range.
Assumptions and limits
- Low-alloy steels, full austenitisation. Compositions far outside Andrews' data that would give a temperature below absolute zero are rejected.
- Compositions are entered as plain weight-per-cent numbers (0.4 for 0.4 % C), unlike the Andrews critical temperatures calculator, which takes them as percentages; the inputs are kept as they are so saved links keep their meaning.
References
- Andrews (1965)
- J. Iron Steel Inst. 203: Ms (°C) = 539 − 423C − 30.4Mn − 17.7Ni − 12.1Cr − 7.5Mo
Questions and answers
4340-type steel (0.4 C, 0.75 Mn, 1.8 Ni, 0.8 Cr, 0.25 Mo)?
Ms about 304 °C.
Why does carbon dominate?
It stabilises austenite strongly: about 42 °C lower per 0.1 % C.
Use?
Set quench and austempering temperatures and judge cracking risk.