FireCADCalc

Noise Dose and 8-Hour Time-Weighted Average

Daily noise dose and 8-hour TWA from up to three exposures at measured levels, by the OSHA 90 dBA, 5 dB exchange rule or the 85 dBA, 3 dB rule.

Thermal power plantProcess steam and utilities

Inputs

Examples: OSHA: 4 h at 95, 3 h at 88, 1 h at 80 dBA3 dB rule: same dayOSHA: 8 h at exactly 90 dBA

Results

A dose above 100 % exceeds the criterion. OSHA counts only levels of 80 dBA and above for the action level and 90 dBA and above for the PEL; this calculator counts every level entered, so against the PEL it can overstate the dose.

Noise dose582.91%
8-hour time-weighted average (dBA)92.630
Permitted time at level 10.79370h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: OSHA: 4 h at 95, 3 h at 88, 1 h at 80 dBA. The inputs, in the units selected above:

InputValue
CriterionOSHA: 90 dBA, 5 dB exchange (29 CFR 1910.95)
Level of exposure 1 (dBA)95.000 -
Duration of exposure 14.0000 h
Level of exposure 2 (dBA)88.000 -
Duration of exposure 23.0000 h
Level of exposure 3 (dBA)80.000 -
Duration of exposure 31.0000 h

Applying the formula below gives:

ResultValue
Noise dose131.54 %
8-hour time-weighted average (dBA)91.978
Permitted time at level 14.0000 h

Open this example in the calculator and change any input.

Formula

\(T = \frac{8\ \text{h}}{2^{(L - L_c)/q}}, \quad D = \sum \frac{C_i}{T_i}, \quad TWA = L_c + \frac{q}{\log_{10} 2}\log_{10} D\)

Variables

Symbol Meaning SI unit
\(\text{rule}\) Criterion -
\(L_1\) Level of exposure 1 (dBA) -
\(C_1\) Duration of exposure 1 s
\(L_2\) Level of exposure 2 (dBA) -
\(C_2\) Duration of exposure 2 s
\(L_3\) Level of exposure 3 (dBA) -
\(C_3\) Duration of exposure 3 s
\(D\) Noise dose -
\(TWA\) 8-hour time-weighted average (dBA) -
\(T_1\) Permitted time at level 1 s

Method and standards

Equal-energy (3 dB) or OSHA (5 dB) exchange rule.

Where it is used

  • Plant noise surveys.
  • Hearing conservation programmes.

Common mistakes

  • Mixing exchange rates.
  • Unweighted instead of A-weighted levels.

Assumptions and limits

  • Steady levels in each period.
  • Every level entered is counted; OSHA counts only levels of 80 dBA and above for the action level and 90 dBA and above for the PEL, so enter only those levels for a strict OSHA comparison.

References

  • 29 CFR 1910.95 Appendix A (OSHA): T = 8/2^((L − 90)/5)
  • D = Σ C/T
  • TWA = 16.61 log₁₀(D) + 90
  • NIOSH 1998 criterion: 85 dBA
  • 3 dB exchange

Questions and answers

4 h at 95, 3 h at 88 and 1 h at 80 dBA (OSHA)?

Dose 132 %, TWA 92.0 dBA.

Why do the rules differ?

OSHA uses a 5 dB exchange; NIOSH and most countries use 3 dB, which is stricter.

What does 100 % mean?

The full permitted daily exposure.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.