FireCADCalc

Day–Night and Day–Evening–Night Noise Levels (Ldn, Lden)

Day–night average sound level Ldn from day and night equivalent levels with the 10 dB night penalty, and Lden with an evening period and 5 dB penalty.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolChemical and fertiliserPulp and paper

Inputs

Examples: 65 / 60 / 52 dBAQuiet residential 50 / 45 / 42

Results

Ldn: day 07–22 (15 h), night 22–07 with +10 dB. Lden (EU): day 12 h, evening 4 h with +5 dB, night 8 h with +10 dB. Indian ambient limits are set separately for day and night Leq.

Day–night level (dBA)50.861
Day–evening–night level (dBA)50.774
24-hour Leq without penalties, from the day–evening–night periods (dBA)47.821

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 65 / 60 / 52 dBA. The inputs, in the units selected above:

InputValue
Day Leq (dBA)65.000 -
Evening Leq (dBA)60.000 -
Night Leq (dBA)52.000 -
Day hours (Ldn)15.000 -
Day hours (Lden)12.000 -
Evening hours (Lden)4.0000 -

Applying the formula below gives:

ResultValue
Day–night level (dBA)64.101
Day–evening–night level (dBA)64.210
24-hour Leq without penalties, from the day–evening–night periods (dBA)62.554

Open this example in the calculator and change any input.

Formula

\(L_{dn} = 10\log_{10}\frac{h_d10^{L_d/10} + (24 - h_d)10^{(L_n + 10)/10}}{24}\) \(L_{den} = 10\log_{10}\frac{h'_d10^{L_d/10} + h_e10^{(L_e + 5)/10} + (24 - h'_d - h_e)10^{(L_n + 10)/10}}{24}\) \(L_{eq,24h} = 10\log_{10}\frac{h'_d10^{L_d/10} + h_e10^{L_e/10} + (24 - h'_d - h_e)10^{L_n/10}}{24}\)

Variables

Symbol Meaning SI unit
\(L_d\) Day Leq (dBA) -
\(L_e\) Evening Leq (dBA) -
\(L_n\) Night Leq (dBA) -
\(h_d\) Day hours (Ldn) -
\(h_d'\) Day hours (Lden) -
\(h_e\) Evening hours (Lden) -
\(L_{dn}\) Day–night level (dBA) -
\(L_{den}\) Day–evening–night level (dBA) -
\(L_{eq,24h}\) 24-hour Leq without penalties, from the day–evening–night periods (dBA) -

Method and standards

Energy average with penalties.

Where it is used

  • Plant boundary noise reporting.
  • Environmental impact assessments.

Common mistakes

  • Adding dB arithmetically.
  • Forgetting the night penalty.

Assumptions and limits

  • Period Leq values measured or predicted. The unpenalised 24-hour Leq uses the three Lden periods, so the evening level counts.

References

  • Day–night level (US EPA, 1974) and Lden (EU Directive 2002/49/EC) definitions

Questions and answers

Why penalise night noise?

The same level disturbs sleep far more than daytime activity; 10 dB is about doubling the loudness.

What is a typical limit?

Ldn around 55 dBA protects residential areas from annoyance (WHO guidance).

What do the defaults represent?

A plant boundary with 65 dBA by day, 60 in the evening and 55 at night.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.