FireCADCalc

Zirconia Oxygen Probe EMF and Oxygen Content

Cell EMF of a zirconia oxygen analyser from the oxygen content and cell temperature by the Nernst equation, and the oxygen content from a measured EMF.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 3 % O₂ at 750 °C against air; 50 mV reading1 % O₂ at 700 °C; 80 mVAir on both sides at 800 °C; 0 mV

20.95 % is dry air. Humid instrument or ambient air holds about 20.6–20.7 %; enter that if the reference air is not dried.

Results

Wet-basis oxygen at the cell: in-situ probes read wet flue gas, extractive analysers usually dry gas.

Cell EMF for the oxygen entered63.778mV
Oxygen for the EMF entered0.46127%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 % O₂ at 750 °C against air; 50 mV reading. The inputs, in the units selected above:

InputValue
Cell temperature750.00 °C
Oxygen in the sample (by volume)3.0000 %
Oxygen in the reference gas20.950 %
Measured cell EMF (to find O₂)50.000 mV

Applying the formula below gives:

ResultValue
Cell EMF for the oxygen entered42.839 mV
Oxygen for the EMF entered2.1679 %

Open this example in the calculator and change any input.

Formula

\(E = \frac{R\, T}{4 F}\, \ln\frac{O_{2,ref}}{O_2}\)

Variables

Symbol Meaning SI unit
\(T\) Cell temperature K
\(O_2\) Oxygen in the sample (by volume) -
\(O_{2,ref}\) Oxygen in the reference gas -
\(E\) Measured cell EMF (to find O₂) V
\(E_{O_2}\) Cell EMF for the oxygen entered V
\(O_{2,E}\) Oxygen for the EMF entered -

Method and standards

Nernst equation with four electrons per O₂ molecule.

Where it is used

  • Boiler O₂ trim.
  • Analyser checks.

Common mistakes

  • Mixing wet and dry O₂.
  • Cell temperature off its set point.

Assumptions and limits

  • The default reference, 20.95 % O₂, is dry air. Reference air carrying moisture has slightly less oxygen (about 20.6–20.7 % at typical humidity), which shifts the reading by a few tenths of a millivolt; analysers usually calibrate this out.

  • Ideal cell, no offset.

References

  • Nernst equation for an oxygen concentration cell
  • E = (R T / 4F) ln(p_ref / p)

Questions and answers

What EMF does 3 % O₂ give at 750 °C against air?

42.8 mV.

Why does the cell need heating?

Zirconia conducts oxygen ions only when hot, typically above 600 °C.

Why is the scale logarithmic?

The EMF follows the log of the oxygen ratio, so low O₂ gives large signals.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.