Worked example
Example: Illustrative 2.5 m, 8 s, 20 m device. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Significant wave height | 2.5000 m |
| Energy period | 8.0000 s |
| Device width (characteristic dimension) | 20.000 m |
| Capture width ratio | 25.000 % |
| Rated power | 750.00 kW |
| Availability | 90.000 % |
| Seawater density | 1,025.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wave power per metre of crest | 24.514 kW/m |
| Absorbed power (capped at rated) | 122.57 kW |
| Capture width | 5.0000 m |
| Annual energy if this sea state persisted | 966.32 MWh |
| Capacity factor in this sea state | 14.708 % |
Open this example in the calculator and change any input.
Formula
\(P_w = \frac{\rho g^2H_s^2T_e}{64\pi}, \quad P_a = \min(CWR\cdot B\cdot P_w,\;P_r)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H_s\) | Significant wave height | m |
| \(T_e\) | Energy period | s |
| \(B\) | Device width (characteristic dimension) | m |
| \(CWR\) | Capture width ratio | - |
| \(P_r\) | Rated power | W |
| \(A_v\) | Availability | - |
| \(\rho\) | Seawater density | kg/m³ |
| \(P_w\) | Wave power per metre of crest | W/m |
| \(P_a\) | Absorbed power (capped at rated) | W |
| \(B\cdot CWR\) | Capture width | m |
| \(E\) | Annual energy if this sea state persisted | J |
| \(CF\) | Capacity factor in this sea state | - |
Method and standards
Wave energy flux.
Where it is used
- Wave site and device screening.
- Coastal engineering wave power estimates.
Common mistakes
- Using the peak period instead of the energy period.
- Using the deep-water formula in shallow water.
Assumptions and limits
- Deep water; one sea state; constant capture width ratio.
References
- Deep-water wave energy flux and capture width
Questions and answers
How much power is in ocean waves?
About 0.49 H_s²T_e kW per metre: a 2.5 m, 8 s sea carries about 25 kW per metre of crest; exposed Atlantic coasts average 40–70 kW/m.
What capture width ratios do devices reach?
Typically 10–40 % of their width, varying strongly with wave period.
What do the defaults represent?
An illustrative 20 m wide device with a 25 % capture width ratio and 750 kW rating in a 2.5 m, 8 s sea, 90 % available.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), ch. 12