Worked example
Example: Illustrative 250 C reservoir, 160 C separator, 50 C condenser, 100 kg/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reservoir temperature (saturated liquid) | 250.00 °C |
| Separator temperature | 160.00 °C |
| Condenser temperature | 50.000 °C |
| Total geofluid flow | 360,000 kg/h |
| Dry turbine efficiency | 85.000 % |
| Generator efficiency | 98.000 % |
| Dead-state (ambient) temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam fraction after flashing | 19.699 % |
| Steam flow to the turbine | 70,918 kg/h |
| Turbine exhaust quality | 87.124 % |
| Wet turbine efficiency | 79.528 % |
| Turbine power | 9.3145 MW |
| Electrical power | 9.1282 MW |
| Electrical output per kg of geofluid | 91.282 kJ/kg |
| Utilisation (exergy) efficiency | 35.450 % |
| Condenser heat | 40.881 MW |
Open this example in the calculator and change any input.
Formula
\(x_2 = \frac{h_1 - h_f(T_{sep})}{h_{fg}(T_{sep})}, \quad h_5 = \frac{h_4 - A\left(1 - \frac{h_6}{h_7 - h_6}\right)}{1 + \frac{A}{h_7 - h_6}}, \quad A = \frac{\eta_{td}}{2}(h_4 - h_{5s}), \quad \eta_u = \frac{\dot W_e}{\dot m e_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{res}\) | Reservoir temperature (saturated liquid) | K |
| \(T_{sep}\) | Separator temperature | K |
| \(T_{cond}\) | Condenser temperature | K |
| \(\dot m\) | Total geofluid flow | kg/s |
| \(\eta_{td}\) | Dry turbine efficiency | - |
| \(\eta_g\) | Generator efficiency | - |
| \(T_0\) | Dead-state (ambient) temperature | K |
| \(x_2\) | Steam fraction after flashing | - |
| \(\dot m_s\) | Steam flow to the turbine | kg/s |
| \(x_5\) | Turbine exhaust quality | - |
| \(\eta_{tw}\) | Wet turbine efficiency | - |
| \(\dot W_t\) | Turbine power | W |
| \(\dot W_e\) | Electrical power | W |
| \(w\) | Electrical output per kg of geofluid | J/kg |
| \(\eta_u\) | Utilisation (exergy) efficiency | - |
| \(\dot Q_c\) | Condenser heat | W |
Method and standards
Single-flash cycle.
Where it is used
- Geothermal field development and plant sizing.
- Checking vendor heat balances.
Common mistakes
- Using a dry-turbine efficiency for wet expansion.
- Taking the reservoir temperature as the separator temperature.
Assumptions and limits
- Saturated-liquid reservoir; no non-condensable gases; no pressure losses in pipes.
References
- Single-flash cycle with Baumann wet-turbine rule and exergy utilisation
Questions and answers
Why is only part of the geofluid used as steam?
Flashing hot brine at a lower pressure turns only a fraction (often 15–25 %) to steam; the rest is reinjected or flashed again in a double-flash plant.
What utilisation efficiency do flash plants reach?
About 30–45 % of the geofluid exergy; double-flash plants gain another 15–25 % of output.
What do the defaults represent?
An illustrative 250 °C liquid reservoir, separator at 160 °C, condenser at 50 °C, 100 kg/s, 85 % dry turbine efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 5