Tidal Stream Turbine Power and Annual Energy

Peak and mean power and annual energy of a tidal stream turbine from spring and neap peak currents, rotor size, power coefficient, cut-in speed and rated power.

Thermal power plant

Inputs

Examples: Illustrative 18 m, 1 MW, 3.0 / 1.6 m/sStrong site 20 m, 2 MW, 4.0 / 2.0 m/sWeak site 12 m, 300 kW, 2.0 / 1.0 m/s

Accepted: 1 to 50 m
Accepted: 0.3 to 6 m/s
Accepted: 0.1 to 6 m/s
Accepted: 0.05 to 0.593
Accepted: 50 to 100 %
Accepted: 0 to 2 m/s
Accepted: 0.001 to 100 MW
Accepted: 990 to 1,050 kg/m³

Results

Current v = V₀|sin θ| through each tide, with the peak V₀ varying sinusoidally between neap and spring; power ½ρAC_Pηv³ between cut-in and rated. Mean found by averaging over both cycles (Simpson). Real sites have asymmetric ebb and flood and diurnal inequality.

Power at the spring peak (uncapped)0.15859MW
Mean power over the spring-neap cycle32.980kW
Annual energy288.90MWh
Capacity factor10.993%
Current at which rated power is reached2.4735m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 18 m, 1 MW, 3.0 / 1.6 m/s. The inputs, in the units selected above:

InputValue
Rotor diameter18.000 m
Spring-tide peak current3.0000 m/s
Neap-tide peak current1.6000 m/s
Power coefficient0.40000 -
Drive-train efficiency90.000 %
Cut-in current0.70000 m/s
Rated power1.0000 MW
Seawater density1,025.0 kg/m³

Applying the formula below gives:

ResultValue
Power at the spring peak (uncapped)1.2676 MW
Mean power over the spring-neap cycle268.59 kW
Annual energy2,352.8 MWh
Capacity factor26.859 %
Current at which rated power is reached2.7720 m/s

Open this example in the calculator and change any input.

Formula

\(P(v) = \frac{1}{2}\rho AC_P\eta v^3, \quad v = V_0|\sin\theta|, \quad V_0 = \bar V + \Delta V\cos\phi\)

Variables

Symbol Meaning SI unit
\(D\) Rotor diameter m
\(V_s\) Spring-tide peak current m/s
\(V_n\) Neap-tide peak current m/s
\(C_P\) Power coefficient -
\(\eta\) Drive-train efficiency -
\(V_{ci}\) Cut-in current m/s
\(P_r\) Rated power W
\(\rho\) Seawater density kg/m³
\(P_{spring}\) Power at the spring peak (uncapped) W
\(\bar P\) Mean power over the spring-neap cycle W
\(E\) Annual energy J
\(CF\) Capacity factor -
\(V_r\) Current at which rated power is reached m/s

Method and standards

Tidal current resource and turbine output.

Where it is used

  • Tidal array screening and resource studies.
  • Comparing with wind and wave options.

Common mistakes

  • Using the spring peak as an average current.
  • Ignoring rated power when computing energy.

Assumptions and limits

  • Symmetric semidiurnal tide; uniform flow over the rotor.

References

  • Tidal current power with semidiurnal and spring-neap variation

Questions and answers

Why do tidal turbines suit seawater so well?

Seawater is 840 times denser than air, so a 3 m/s current carries about 14 kW/m², as much as a 28 m/s wind.

What capacity factors do they reach?

About 25–40 %: the current is predictable but drops to zero four times a day and varies through the spring-neap cycle.

What do the defaults represent?

An illustrative 18 m, 1 MW turbine at a site with 3.0 m/s spring and 1.6 m/s neap peak currents, C_P 0.40 and 0.7 m/s cut-in.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), ch. 13

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.