Worked example
Example: Illustrative 18 m, 1 MW, 3.0 / 1.6 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rotor diameter | 18.000 m |
| Spring-tide peak current | 3.0000 m/s |
| Neap-tide peak current | 1.6000 m/s |
| Power coefficient | 0.40000 - |
| Drive-train efficiency | 90.000 % |
| Cut-in current | 0.70000 m/s |
| Rated power | 1.0000 MW |
| Seawater density | 1,025.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power at the spring peak (uncapped) | 1.2676 MW |
| Mean power over the spring-neap cycle | 268.59 kW |
| Annual energy | 2,352.8 MWh |
| Capacity factor | 26.859 % |
| Current at which rated power is reached | 2.7720 m/s |
Open this example in the calculator and change any input.
Formula
\(P(v) = \frac{1}{2}\rho AC_P\eta v^3, \quad v = V_0|\sin\theta|, \quad V_0 = \bar V + \Delta V\cos\phi\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Rotor diameter | m |
| \(V_s\) | Spring-tide peak current | m/s |
| \(V_n\) | Neap-tide peak current | m/s |
| \(C_P\) | Power coefficient | - |
| \(\eta\) | Drive-train efficiency | - |
| \(V_{ci}\) | Cut-in current | m/s |
| \(P_r\) | Rated power | W |
| \(\rho\) | Seawater density | kg/m³ |
| \(P_{spring}\) | Power at the spring peak (uncapped) | W |
| \(\bar P\) | Mean power over the spring-neap cycle | W |
| \(E\) | Annual energy | J |
| \(CF\) | Capacity factor | - |
| \(V_r\) | Current at which rated power is reached | m/s |
Method and standards
Tidal current resource and turbine output.
Where it is used
- Tidal array screening and resource studies.
- Comparing with wind and wave options.
Common mistakes
- Using the spring peak as an average current.
- Ignoring rated power when computing energy.
Assumptions and limits
- Symmetric semidiurnal tide; uniform flow over the rotor.
References
- Tidal current power with semidiurnal and spring-neap variation
Questions and answers
Why do tidal turbines suit seawater so well?
Seawater is 840 times denser than air, so a 3 m/s current carries about 14 kW/m², as much as a 28 m/s wind.
What capacity factors do they reach?
About 25–40 %: the current is predictable but drops to zero four times a day and varies through the spring-neap cycle.
What do the defaults represent?
An illustrative 18 m, 1 MW turbine at a site with 3.0 m/s spring and 1.6 m/s neap peak currents, C_P 0.40 and 0.7 m/s cut-in.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), ch. 13