FireCADCalc

Silica Geothermometer and Amorphous Silica Scaling Index

Reservoir temperature from the silica in a spring or well sample (quartz geothermometer, with or without steam loss) and the silica scaling index after flashing.

Thermal power plant

Inputs

Examples: Illustrative 400 mg/kg, maximum steam loss, 160 C separatorWell sample 350 mg/kg, no steam loss, 150 CLow silica 150 mg/kg, maximum loss, 110 C flash

Accepted: 10 to 1,000
Accepted: 90 to 300 °C

Results

Fournier–Potter quartz correlations (valid about 20–340 °C) and the Fournier–Rowe amorphous silica solubility log S = 4.52 − 731/T (S in mg/kg, T in K). SI above 1 means the brine is supersaturated in amorphous silica and may scale pipes, separators and reinjection wells; kinetics often allow a short-lived SI up to about 1.2.

Quartz geothermometer, no steam loss (1309/(5.19 − log S))221.57°C
Reservoir temperature (Fournier–Potter, chosen steam-loss case)223.33°C
Silica in the reservoir liquid (mg/kg)350.00
Steam fraction at the separator15.461%
Silica in the separated brine (mg/kg)414.01
Amorphous silica solubility at T_sep (mg/kg)620.13
Saturation index C/S_am0.66763

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 400 mg/kg, maximum steam loss, 160 C separator. The inputs, in the units selected above:

InputValue
Silica measured in the sample (mg/kg)400.00 -
Steam loss before samplingMaximum (flashed to atmospheric pressure)
Separator or flash temperature to check for scaling160.00 °C

Applying the formula below gives:

ResultValue
Quartz geothermometer, no steam loss (1309/(5.19 − log S))232.66 °C
Reservoir temperature (Fournier–Potter, chosen steam-loss case)213.67 °C
Silica in the reservoir liquid (mg/kg)312.18
Steam fraction at the separator11.477 %
Silica in the separated brine (mg/kg)352.65
Amorphous silica solubility at T_sep (mg/kg)679.77
Saturation index C/S_am0.51878

Open this example in the calculator and change any input.

Formula

\(T = \frac{1309}{5.19 - \log_{10}S} - 273.15, \quad C = \frac{Q(T_{res})}{1 - x_{sep}}, \quad SI = \frac{C}{S_{am}(T_{sep})}, \quad \log_{10}S_{am} = 4.52 - \frac{731}{T}\)

Variables

Symbol Meaning SI unit
\(S\) Silica measured in the sample (mg/kg) -
\(\text{loss}\) Steam loss before sampling -
\(T_{sep}\) Separator or flash temperature to check for scaling K
\(T_{qtz}\) Quartz geothermometer, no steam loss (1309/(5.19 − log S)) K
\(T_{res}\) Reservoir temperature (Fournier–Potter, chosen steam-loss case) K
\(Q\) Silica in the reservoir liquid (mg/kg) -
\(x_{sep}\) Steam fraction at the separator -
\(C\) Silica in the separated brine (mg/kg) -
\(S_{am}\) Amorphous silica solubility at T_sep (mg/kg) -
\(SI\) Saturation index C/S_am -

Method and standards

Silica geochemistry.

Where it is used

  • Geothermal exploration and resource assessment.
  • Separator temperature and reinjection limits.

Common mistakes

  • Using the no-steam-loss case for a boiling spring.
  • Ignoring pH effects on silica polymerisation.

Assumptions and limits

  • Equilibrium with quartz at depth; no dilution or re-equilibration on the way up.

References

  • Fournier–Potter silica geothermometers and Fournier–Rowe amorphous silica solubility

Questions and answers

How can a hot spring tell the reservoir temperature?

Quartz solubility rises with temperature; water that equilibrated with quartz at depth and cooled quickly keeps its silica, which acts as a thermometer.

Why does flashing cause scaling?

Steam carries no silica, so the remaining brine is concentrated while it also cools, and amorphous silica solubility falls with temperature.

What do the defaults represent?

An illustrative spring sample with 400 mg/kg silica that flashed to atmospheric pressure, checked at a 160 °C separator.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fournier and Potter, A revised and expanded silica (quartz) geothermometer, Geothermal Resources Council Bulletin 11 (1982) 3–12, Fournier and Rowe, The solubility of amorphous silica in water at high temperatures and high pressures, American Mineralogist 62 (1977) 1052–1056, DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 2 and 5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.