Worked example
Example: Illustrative 400 mg/kg, maximum steam loss, 160 C separator. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Silica measured in the sample (mg/kg) | 400.00 - |
| Steam loss before sampling | Maximum (flashed to atmospheric pressure) |
| Separator or flash temperature to check for scaling | 160.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Quartz geothermometer, no steam loss (1309/(5.19 − log S)) | 232.66 °C |
| Reservoir temperature (Fournier–Potter, chosen steam-loss case) | 213.67 °C |
| Silica in the reservoir liquid (mg/kg) | 312.18 |
| Steam fraction at the separator | 11.477 % |
| Silica in the separated brine (mg/kg) | 352.65 |
| Amorphous silica solubility at T_sep (mg/kg) | 679.77 |
| Saturation index C/S_am | 0.51878 |
Open this example in the calculator and change any input.
Formula
\(T = \frac{1309}{5.19 - \log_{10}S} - 273.15, \quad C = \frac{Q(T_{res})}{1 - x_{sep}}, \quad SI = \frac{C}{S_{am}(T_{sep})}, \quad \log_{10}S_{am} = 4.52 - \frac{731}{T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Silica measured in the sample (mg/kg) | - |
| \(\text{loss}\) | Steam loss before sampling | - |
| \(T_{sep}\) | Separator or flash temperature to check for scaling | K |
| \(T_{qtz}\) | Quartz geothermometer, no steam loss (1309/(5.19 − log S)) | K |
| \(T_{res}\) | Reservoir temperature (Fournier–Potter, chosen steam-loss case) | K |
| \(Q\) | Silica in the reservoir liquid (mg/kg) | - |
| \(x_{sep}\) | Steam fraction at the separator | - |
| \(C\) | Silica in the separated brine (mg/kg) | - |
| \(S_{am}\) | Amorphous silica solubility at T_sep (mg/kg) | - |
| \(SI\) | Saturation index C/S_am | - |
Method and standards
Silica geochemistry.
Where it is used
- Geothermal exploration and resource assessment.
- Separator temperature and reinjection limits.
Common mistakes
- Using the no-steam-loss case for a boiling spring.
- Ignoring pH effects on silica polymerisation.
Assumptions and limits
- Equilibrium with quartz at depth; no dilution or re-equilibration on the way up.
References
- Fournier–Potter silica geothermometers and Fournier–Rowe amorphous silica solubility
Questions and answers
How can a hot spring tell the reservoir temperature?
Quartz solubility rises with temperature; water that equilibrated with quartz at depth and cooled quickly keeps its silica, which acts as a thermometer.
Why does flashing cause scaling?
Steam carries no silica, so the remaining brine is concentrated while it also cools, and amorphous silica solubility falls with temperature.
What do the defaults represent?
An illustrative spring sample with 400 mg/kg silica that flashed to atmospheric pressure, checked at a 160 °C separator.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Fournier and Potter, A revised and expanded silica (quartz) geothermometer, Geothermal Resources Council Bulletin 11 (1982) 3–12, Fournier and Rowe, The solubility of amorphous silica in water at high temperatures and high pressures, American Mineralogist 62 (1977) 1052–1056, DiPippo, Geothermal Power Plants: Principles, Applications, Case Studies and Environmental Impact, 4th ed. (Butterworth-Heinemann, 2016), ch. 2 and 5