FireCADCalc

Salinity Gradient Power: Osmotic Pressure and PRO Output

Osmotic pressure of seawater and river water, the mixing energy per cubic metre of fresh water, and the best power density of pressure-retarded osmosis.

Thermal power plant

Inputs

Examples: Illustrative 35 / 0.5 g/kg at 15 CSalt-works brine 150 g/kg vs seawaterWarm 25 C, better membrane 3

Accepted: 0 to 200 g/kg
Accepted: 0 to 50 g/kg
Accepted: 0.85 to 56.85 °C
Accepted: 0.5 to 1.2
Accepted: 0.01 to 20

Results

Osmotic pressure π = 2φmρ_wRT for NaCl molality m. Mixing a small volume of fresh water into a large sea releases at most about Δπ per m³. PRO: W/A = A_w(Δπ − ΔP)ΔP, largest at ΔP = Δπ/2; concentration polarisation and salt leakage cut real values to about a third or less.

Osmotic pressure of seawater156.74bar
Osmotic pressure difference124.52bar
Mixing energy per m³ of fresh water into much more seawater (kWh/m³)3.4589
Best hydraulic pressure Δπ/262.261bar
Maximum PRO power density107.68W/m²
Water flux at the best pressure62.261L/(m²·h)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 35 / 0.5 g/kg at 15 C. The inputs, in the units selected above:

InputValue
Seawater salinity (as NaCl)35.000 g/kg
River water salinity (as NaCl)0.50000 g/kg
Water temperature15.000 °C
Osmotic coefficient (about 0.93 for seawater)0.93000 -
Membrane water permeability (L per m², hour and bar)1.5000 -

Applying the formula below gives:

ResultValue
Osmotic pressure of seawater27.632 bar
Osmotic pressure difference27.250 bar
Mixing energy per m³ of fresh water into much more seawater (kWh/m³)0.75696
Best hydraulic pressure Δπ/213.625 bar
Maximum PRO power density7.7353 W/m²
Water flux at the best pressure20.438 L/(m²·h)

Open this example in the calculator and change any input.

Formula

\(\pi = 2\phi m\rho_wRT, \quad \frac{W}{A} = A_w(\Delta\pi - \Delta P)\Delta P \le \frac{A_w\Delta\pi^2}{4}\)

Variables

Symbol Meaning SI unit
\(S_{sea}\) Seawater salinity (as NaCl) kg/kg
\(S_{fresh}\) River water salinity (as NaCl) kg/kg
\(T\) Water temperature K
\(\phi\) Osmotic coefficient (about 0.93 for seawater) -
\(A_w\) Membrane water permeability (L per m², hour and bar) -
\(\pi_{sea}\) Osmotic pressure of seawater Pa
\(\Delta\pi\) Osmotic pressure difference Pa
\(E\) Mixing energy per m³ of fresh water into much more seawater (kWh/m³) -
\(\Delta P_{opt}\) Best hydraulic pressure Δπ/2 Pa
\(W/A\) Maximum PRO power density W/m²
\(J_w\) Water flux at the best pressure m/s

Method and standards

Osmotic pressure and PRO power.

Where it is used

  • Screening osmotic power at river mouths and salt works.
  • Understanding RO energy (the reverse process).

Common mistakes

  • Using seawater's osmotic pressure as the energy for a finite sea volume.
  • Ignoring concentration polarisation.

Assumptions and limits

  • NaCl solution; ideal-dilute van 't Hoff with an osmotic coefficient.

References

  • Van 't Hoff osmotic pressure and pressure-retarded osmosis

Questions and answers

How much energy is in a river meeting the sea?

About 0.7–0.8 kWh per m³ of fresh water at most, equivalent to a waterfall about 270 m high.

Why has osmotic power not spread?

Membranes give only a few W/m² in practice, so very large and cheap membrane areas are needed; fouling by river water adds cost.

What do the defaults represent?

An illustrative 35 g/kg seawater and 0.5 g/kg river water at 15 °C, osmotic coefficient 0.93 and a membrane of 1.5 L/(m²·h·bar).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), ch. 12

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.