FireCADCalc

Ocean Thermal Energy Conversion (OTEC) Net Power

Gross power, seawater pumping power and net output of a closed-cycle OTEC plant from warm and cold seawater temperatures and flows, pinches and cycle quality.

Thermal power plant

Inputs

Examples: Illustrative 26/5 C, 5 m3/s eachWarm 28 C, 4 C, larger cold flowMarginal 24/6 C

Accepted: 11.85 to 36.85 °C
Accepted: 0 to 19.85 °C
Accepted: 36 to 360,000 m³/h
Accepted: 36 to 360,000 m³/h
Accepted: 0.5 to 10 K
Accepted: 0.5 to 8 K
Accepted: 30 to 100 %
Accepted: 0 to 50 m
Accepted: 0 to 50 m
Accepted: 30 to 100 %
Accepted: 990 to 1,050 kg/m³
Accepted: 3.8 to 4.2 kJ/(kg·K)

Results

Closed cycle: evaporating at T_w − ΔT_w − δ and condensing at T_c + ΔT_c + δ, with the cold-water rise from the heat rejected; cycle efficiency is the chosen fraction of the Carnot value between those temperatures. Pumping power ρg(Q_wH_w + Q_cH_c)/η_p typically takes 20–40 % of the gross output.

Heat taken from warm water57.257MW
Cold water temperature rise2.2371K
Working fluid evaporating temperature23.000°C
Working fluid condensing temperature7.7371°C
Cycle efficiency4.1230%
Gross power2,360.7kW
Seawater pumping power603.11kW
Net power1,757.6kW
Carnot efficiency of the seawater temperatures7.9695%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 26/5 C, 5 m3/s each. The inputs, in the units selected above:

InputValue
Warm surface water temperature26.000 °C
Cold deep water temperature5.0000 °C
Warm water flow18,000 m³/h
Cold water flow18,000 m³/h
Warm water temperature drop3.0000 K
Pinch in each heat exchanger2.0000 K
Cycle efficiency as a fraction of Carnot75.000 %
Warm-water pumping head3.0000 m
Cold-water pumping head (pipe friction and density)5.0000 m
Pump and motor efficiency80.000 %
Seawater density1,025.0 kg/m³
Seawater specific heat3.9900 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Heat taken from warm water61.346 MW
Cold water temperature rise2.9152 K
Working fluid evaporating temperature21.000 °C
Working fluid condensing temperature9.9152 °C
Cycle efficiency2.8263 %
Gross power1,733.8 kW
Seawater pumping power502.59 kW
Net power1,231.2 kW
Carnot efficiency of the seawater temperatures7.0199 %

Open this example in the calculator and change any input.

Formula

\(T_e = T_w - \Delta T_w - \delta, \quad T_k = T_c + \Delta T_c + \delta, \quad \eta = f\left(1 - \frac{T_k}{T_e}\right), \quad P_n = \eta\rho cQ_w\Delta T_w - \frac{\rho g(Q_wH_w + Q_cH_c)}{\eta_p}\)

Variables

Symbol Meaning SI unit
\(T_w\) Warm surface water temperature K
\(T_c\) Cold deep water temperature K
\(Q_w\) Warm water flow m³/s
\(Q_c\) Cold water flow m³/s
\(\Delta T_w\) Warm water temperature drop K
\(\delta\) Pinch in each heat exchanger K
\(f\) Cycle efficiency as a fraction of Carnot -
\(H_w\) Warm-water pumping head m
\(H_c\) Cold-water pumping head (pipe friction and density) m
\(\eta_p\) Pump and motor efficiency -
\(\rho\) Seawater density kg/m³
\(c\) Seawater specific heat J/(kg·K)
\(\dot Q_{in}\) Heat taken from warm water W
\(\Delta T_c\) Cold water temperature rise K
\(T_e\) Working fluid evaporating temperature K
\(T_k\) Working fluid condensing temperature K
\(\eta\) Cycle efficiency -
\(P_g\) Gross power W
\(P_p\) Seawater pumping power W
\(P_n\) Net power W
\(\Delta T/T_w\) Carnot efficiency of the seawater temperatures -

Method and standards

OTEC energy balance.

Where it is used

  • Screening tropical island OTEC projects.
  • Teaching low-temperature heat engines.

Common mistakes

  • Using the full sea temperature difference for the cycle.
  • Forgetting the pumping power of the long cold-water pipe.

Assumptions and limits

  • Steady state; constant seawater properties; cycle quality entered.

References

  • Closed-cycle OTEC energy balance with exchanger pinches

Questions and answers

Why does OTEC need enormous water flows?

With only about 20 K between surface and deep water, the cycle converts 2–3 % of the heat; a megawatt needs several cubic metres per second of each stream.

Where is OTEC possible?

Tropical seas where the surface is above about 25 °C and water at 1,000 m is below about 5 °C, within reach of the coast or a floating platform.

What do the defaults represent?

An illustrative plant with 26 °C surface and 5 °C deep water, 5 m³/s of each, a 3 K warm-water drop, 2 K pinches and 75 % of Carnot.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), ch. 14

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.